Changeover and monitoring module UFC107E Technical data changeover and monitoring module UFC107E Insulation coordination acc. to IEC 60664-1 Evaluator EDS461-L Rated insulation voltage AC 250 VRated impulse voltage/pollution degree 4 kV/3 Measuring current transformer type W10/8000Response sensitivity 0.2…1 mA Number of measuring channels 12 (max. 1068) Scanning time for 12 channels ≤ 10 s Interface Interface/protocol RS-485/BMSBaud rate 9.6 kbit / s Cable length ≤ 1200 mRecommended cable Power unit/ switching elements Switching elements latched contactorsRated operational voltage U
e AC 230 VOperating range U
e 0.8…1.15 x U
e Frequency f
e 50…60 HzRated operational current I Supply voltage devices
e (acc. to IEC 60364-7-710) see ordering informationFuse see ordering information Utilization category AC-3 Changeover period, adjustable ≤ 0.5 s…20 s
(shielded, shield connected to PE on one side) min. J-Y(St)Y 2 x 0.6Terminating resistor 120 Supply voltage devices U Switching elements (alarm contacts PRC487) Ω (0.25 W)Device address, BMS bus PRC487: 2…90 – 107TD47: 2…30 PGH: 111…119 – EDS: 1…90 Factory-set device address PRC487: 4 – 107TD47: 3 – PGH: 111 – EDS: 5 (6) Number of changeover contacts 2 x 1 changeover contactOperating principle N/C operation
S AC 230 VOperating range of U
S 0.8…1.15 x U
e Switching elements (alarm contacts EDS) Frequency range of U
S 50…60 HzPower consumption see ordering information Number of changeover contacts 1 changeover contactOperating principle, adjustable N/C operation Control and indicating device PRC487 Contact data acc. to IEC 60947-5-1 Display, characters LCD, illuminated, 2 x 16 charactersControl inputs ≤ DC 5 V Electrical service life, number of cycles 10.000Utilization category AC-13 AC-14 DC-12 DC-12 DC-12 Rated operational voltage U
2.2 Voltage monitoring Response value undervoltage, adjustable 0.7…0.9 x U
e Response value overvoltage 1.15 x U
e Response time t
an 50…250 msResponse time t
e 230 V 230 V 24 V 110 V 220 VRated operational current I
off adjustable (50 ms steps) 0…9950 msReturn transfer time t
e 5 A 3 A 1 A 0,2 A 0,1 AMinimum contact load 1 mA at AC / DC > 10 V
on adjustable (1 s steps) 0…249 sPause time, adjustable (50 ms steps) 0…9950 ms Terminals Control unit Connection cage clamp spring terminal Connection properties rigid/flexible/conductor sizes 0.08…2.5 mm A-ISOMETER® 107TD47 Display, characters LCD, illuminated, 2 x 16 charactersTest button internal/ external
2 /AWG 28-12Stripping length 8…9 mm Insulation monitoring 107TD47 Response value R
an adjustable 50…500 k Ω Power feeding unit Relative percentage error 0…+10 % Hysteresis ≤ 25 % Response time t Connection cage clamp spring terminal Connection properties rigid/flexible/conductor sizes 6…35 mm
2 /AWG 8-2Stripping length 23 mm
an at R
F = 0.5 x R
an and C
e = 1µF ≤ 3 sMeasuring voltage U
m ≤ 12 VMeasuring current Im (at R Outgoing circuits
F = 0 Ω ) ≤ 50 µAInternal DC resistance R Connection cage clamp spring terminal Connection properties rigid/flexible/conductor sizes 0.08…2.5 mm
i ≥ 240 k Ω
2 /4 mm
2 /AWG 28-12Stripping length 6…7 mm Impedance Z
i at 50 Hz ≥ 200 k Ω Permissible extraneous DC voltage U
fg ≤ DC 375 VPermissible system leakage capacitance C
e ≤ 1 µF General data EMC immunity acc. to EN 61000-6-2EMC emission acc. to EN 61000-6-4 Classification of climatic conditions acc. to IEC 60721 Stationary use 3K5 Transport 2K3 Long-time storage 1K4 Operating temperature -10 °C…+55 °C Classification of mechanical conditions acc. to IEC 60721 Stationary use 3M4 Transport 2M1 Long-time storage 1M3 Operating mode continuous operation Mounting position vertical Degree of protection, internal components /terminals (DIN EN 60529) IP30 / IP20 Mounting into standard distribution panels see table “Dimensions and weights” Flammability class UL94V-0 Product standard IEC 60364-7-710 / DIN VDE 0100-710 (VDE 0100-710) Operating manual TGH1378 Weight table “Dimensions and weights” Load monitoring 107TD47 Response value, adjustable 5…50 AHysteresis ≤ 4 % Temperature influence ≤ 0.15 %/ °C Temperature monitoring 107TD47 Response value 4 k Ω Release value 1.6 k Ω PTC resistors acc. to DIN 44081 max. 6 in series Test device PGH474 Test current IT ≤ 1 mATest pulse/break 2 s / 4 s
Main catalogue part 2 – 05.2008/Hospital engineering 43
DirectIndustry's Virtual Technical Library: PDF Catalogue | Technical Documentation | Brochure | Manual | Industrial directory | Specifications | Characteristics
Search Go
page 1 p.1
page 2 p.2
page 3 p.3
page 4 p.4
page 5 p.5
page 6 p.6
page 7 p.7
page 8 p.8
page 9 p.9
page 10 p.10
page 11 p.11
page 12 p.12
page 13 p.13
page 14 p.14
page 15 p.15
page 16 p.16
page 17 p.17
page 18 p.18
page 19 p.19
page 20 p.20
page 21 p.21
page 22 p.22
page 23 p.23
page 24 p.24
page 25 p.25
page 26 p.26
page 27 p.27
page 28 p.28
page 29 p.29
page 30 p.30
page 31 p.31
page 32 p.32
page 33 p.33
page 34 p.34
page 35 p.35
page 36 p.36
page 37 p.37
page 38 p.38
page 39 p.39
page 40 p.40
page 41 p.41
page 42 p.42
page 43 p.43
page 44 p.44
page 45 p.45
page 46 p.46
page 47 p.47
page 48 p.48
page 49 p.49
page 50 p.50
Pages:
1-50
51-100
101-150
151-196
pdf-page pdf di En 2008-11-47-23