BD SENSORS GmbH
BD-Sensors-Straße 1 Tel: +49 (0) 92 35 / 98 11- 0 www.bdsensors.com
D - 95199 Thierstein Fax: +49 (0) 92 35 / 98 11- 11 info@bdsensors.de
Technical Data
DS 6
Electronic OEM Pressure
Switch Fluid
Input pressure range
Nominal pressure gauge [bar] 2 5 10 20 50 100 200 400
Nominal pressure abs. [bar] 2 5 10 20 50 100 200 400
Overpressure [bar] 7 12 25 50 120 250 400 600
Supply
Supply voltage VS 12 ... 30 VDC
Current consumption max. 14 mA (without contacts)
Contacts
Number standard: 1 optional: 2
Type PNP
Switching performance max. 300 mA, short-circuit proof
Accuracy of contacts IEC 60770: ± 1 % FSO BFSL: ± 0.5 % FSO
Minimum hysteresis of contacts ± 0.5 % FSO
Repeatability ± 0.2 % FSO
Status indication SP 1: green SP 2: yellow
Switching function 1 standard: n/o optional: n/c
Switching mode 1 standard: hysteresis mode optional: window mode
Switch on point 1 standard: factory setting 80 % FSO
others: specify on order; adjustable range 5 ... 100 % FSO
Switch off point 1 standard: factory setting 75 % FSO
others: specify on order; adjustable range 5 ... 100 % FSO
Switch on / switch off delay 1 standard: off
others: specify on order, adjustable range from 10 msec to 90 sec (step 10 msec)
Switching frequency 200 Hz (without switching delay)
Switching cycles > 100 x 106
1 Parameters can be programmed by customer either with the programming kit CIS 685 / CIS 686 or with the programming device P6
(available as accessories).
Thermal effects (Offset and Span) / Permissible temperatures
Thermal error ± 0.3 % FSO / 10 K in compensated range -25 ... 85 °C
Permissible temperatures medium / electronics / environment: -25 ... 85 °C storage: -40 ... 85 °C
Applications
. mechanical enginering / hydraulics
. measuring, control and
process technology
Characteristics
. nominal pressure ranges from
0 … 2 bar up to 0 … 400 bar
. 1 or 2 contacts
. configurable via PC or
programming device P6
. optional:
- oil- and fat free version
- oxygen application
|
|