Tank Level Indicating Systems - 1

LEVEL Tank Level Indicating Systems SHtCnmeasureBarksdale CONTROL PRODUCTS Barksdale, Inc./Barksdale GmbH A Subsidiary of Crane Co.

Open the catalog to page 1
Tank Level Indicating Systems - 2

Tank Level Indicating Systems Tank Level Indicating Systems in Brass or Stainless Steel Tank Level Indicating Systems in Stainless Steel with Ex-approval for Category 1 Specifications are subject to changes without notice. Barksdale Tank Level Indicating Systems 12 / 04 TLI US 01/1

Open the catalog to page 2
Tank Level Indicating Systems - 3

Tank Level Indicating Systems The Barksdale Tank Level Indicating Systems are sensors for remote indication level of liquid media. They operate according to the float principle with magnetic trans-mission (Permanent magnet, Reed switch and resistor chain). The liquid level is indicated on indicating instruments connected to the sensor. Typical Applications for Tank Level Indicating Systems: Waste water and sewage plants, filling and charging containers, heating oil tanks, remote level indication for rivers, canals and basins, radioactive fluids, tank trucks, drinking water and fuel containers...

Open the catalog to page 3
Tank Level Indicating Systems - 4

Tank Level Indicating Systems Reed contact chain The stem contains a full length internal network tapped by magnetically actuated Reed switches mounted at 6,4 mm intervals. A constant voltage across the resistance forms the voltage divider network. Tap switches are connected to a common conductor via series resistors to the receiver meter and are actuated by bar magnets within the float as is traverses the transmitter stem. The float varies the tap point on this voltage divider by raising and falling with liquid level. All wetted parts are made of stainless steel or brass and are available...

Open the catalog to page 4
Tank Level Indicating Systems - 5

Tank Level Indicating Systems The transmitters can be installed from outside through the tank top or tank bottom by using a mounting plug or flange. The mounting position is vertical with a maximum angle of inclination of 30 degrees. The level sensor and additional instruments are maintenance free in applications in clean media. The maintenance of the level sensor consists of an occasional „wipe-off“ cleaning from time to time in excessively contaminated liquids. For the sensor connection shielded cable or wiring is recommended but not necessary. Barksdale Tank Level Indicating Systems The...

Open the catalog to page 5
Tank Level Indicating Systems - 6

Tank Level Indicating Systems Specifications are subject to changes without notice. Barksdale Tank Level Indicating Systems 12 / 04 TLI US 01/1

Open the catalog to page 6
Tank Level Indicating Systems - 7

Specifications are subject to changes without notice. Barksdale Tank Level Indicating Systems 12 / 04 TLI US 01/1

Open the catalog to page 7
Tank Level Indicating Systems - 8

Tank Level Indicating Systems [UJ©[§ ®@@© USE 3000 - Level Sensor up to 3000 mm Length Technical Data Max. Length L0 : 3000 mm Materials : Stainless steel (1.4571, 1.4404), brass, other material on request Mounting Element : Stainless steel (1.4571, 1.4404), tank screw or flange Stem : Stainless steel (1.4571), brass, : Stainless steel (1.4571) - VA44, 0 = 44 mm, oval min. media density = 0,9 g/cm3 max. pressure = 25 bar - VA52, 0 = 52 mm, oval min. media density = 0,74 g/cm3 max. pressure = 25 bar - VA80, 0 = 82 mm, ball min. media density = 0,5 g/cm3 max. pressure = 16 bar : ST1...

Open the catalog to page 8
Tank Level Indicating Systems - 9

Tank Level Indicating Systems Specifications are subject to changes without notice. Barksdale Tank Level Indicating Systems 12 / 04 TLI US 01/1 Order number example Type Series Material Mounting Electrical Float Type Screen Meas. Length Options Element Connection LM

Open the catalog to page 9
Tank Level Indicating Systems - 10

Tank Level Indicating Systems %[p)@ w USE 6000 - Level Sensor up to 6000 mm Length Technical Data Max. Length L0 : 6000 mm Materials : Stainless steel (1.4571, 1.4404), brass, other material on request Mounting Element : Stainless steel (1.4571, 1.4404), tank screw or flange Stem : Stainless steel (1.4571), brass, : Stainless steel (1.4571) VA100, 0 = 105 mm, oval min. media density = 0,62 g/cm3 max. pressure = 32 bar : Buna-N BN 42, 0 = 42 mm min. media density = 0,55 g/cm3 max. pressure = 15 bar : ST1 - Cube plug DIN43650 (3-pin + earth) PG - Cable gland PG 13,5 incl. 1,5 m...

Open the catalog to page 10
Tank Level Indicating Systems - 11

Tank Level Indicating Systems %[p)@ M Dimensions (in mm) Specifications are subject to changes without notice. Barksdale Tank Level Indicating Systems 12 / 04 TLI US 01/1 Mounting Electrical Float Type Element Connection Screen Meas. Length Options LM Type Series

Open the catalog to page 11
Tank Level Indicating Systems - 12

USE 3200 - Level Sensor for Applications in Category 1 Technical Data Max. Length L0 : 3000 mm tank screw or flange Stem : Stainless steel (1.4571), 0 = 13 x 1 mm - VX44, 0 = 44 mm, oval min. media density = 0,9 g/cm3 max. pressure = 25 bar - VX52, 0 = 52 mm, oval min. media density = 0,73 g/cm3 max. pressure = 25 bar - VX80, 0 = 82 mm, ball min. media density = 0,5 g/cm3 max. pressure = 16 bar Electrical Connection : KX4 - Aluminum terminal box (75 x 80 x 57 mm, 3 terminals) KLS - Aluminum terminal box incl. transducer MUEX (75 x 80 x 57 mm) Protection Class : KLX, KLS...

Open the catalog to page 12
Tank Level Indicating Systems - 13

Specifications are subject to changes without notice. Barksdale Tank Level Indicating Systems 12 / 04 TLI US 01/1 Dimensions (in mm) Order number example Type Series Material Mounting Electrical Float Type Screen Meas. Length Options Element Connection LM

Open the catalog to page 13
Tank Level Indicating Systems - 14

USE 6200 - Level Sensor for Applications in Category 1 Electrical Connections Technical data Max. Length L0 : 6000 mm Mounting Element : Stainless steel (1.4571, 1.4408), tank screw or flange Stem : Stainless steel (1.4571), 0 = 18 x 1 mm (if necessary with mounting strap) Float : Stainless steel (1.4571) VX100, 0 = 105 mm, oval min. media density = 0,62 g/cm3 max. pressure = 32 bar : Buna-N BN 42, 0 = 42 mm min. media density = 0,55 g/cm3 max. pressure = 15 bar Electrical Connection : KX4 - Aluminum terminal box (75 x 80 x 57 mm, 3 terminals) KLS - Aluminum...

Open the catalog to page 14
Tank Level Indicating Systems - 15

Tank Level Indicating Systems %[°)® QHS Specifications are subject to changes without notice. Barksdale Tank Level Indicating Systems 12 / 04 TLI US 01/1 Type Series Material Mounting Electrical Float Type Screen Meas. Length Options Element Connection LM

Open the catalog to page 15

All Barksdale catalogs and technical brochures

  1. BDS3000

    3 Pages

  2. BLS3000

    3 Pages

  3. BTS3000

    3 Pages

  4. BPS3000

    3 Pages

  5. UDS3V3

    2 Pages

  6. P1H

    2 Pages

  7. UNS1000

    4 Pages

  8. UNS2000

    4 Pages

  9. Oil & Gas

    12 Pages

  10. 52341 series

    4 Pages

  11. 52321 Series

    4 Pages

  12. 55521 Series

    4 Pages

  13. Flow Switches

    16 Pages

  14. Level Switches

    28 Pages

  15. 52462 Series

    4 Pages