Mechanical Temperature Switches - Barksdale - #3 |
|
You may also be interested in
Relative pressure sensor, Level transmitter, Magnetic level indicator, Float level sensor, Piston pressure switch
Text version of the page
Specifications are subject to changes without notice. 11 / 05 KTM-US 923-0876 01/1
Conventional
switch
Barksdale
switch
Set point
Ambient temperature in °C
Set point variationdue to ambient change in °C
+3,9
+3,3
+2,7
+2,2
+1,6
+1,1
+0,5
0
-1,5
-1,1
-1,6
-2,2
-2,7
-3,3
-3,9
-4,4
-51 -34 -18 -1 +16 +32 +49 +65
3
Mechanical Temperature Switches
Ambient Temperature Compensation
and switching accuracy
Barksdale Temperature Switches incorporate a compensating
device to cancel out the adverse effects of ambient fluctuation.
Curves reflect averages of a series of tests. Results of specific
conditions are available on request. Barksdale switches are
designed for ±1/2 percent accurate response through the mid
60% of the adjustable range (±2% at min. or max. adjustable
set point).
Example:
In conventional switches an ambient temperature fluctuation
between -50 °C and +75 °C produces a swing of 10 degrees
or more - in Barksdale switches extreme fluctuation of ambient
may result in a 2 to 3 degrees swing.
Description
Cable gland
(provided)
Weatherproof
protection cap,
tamperproof
SeIf-locking adjustment,
field-adjustable with
calibrated dial
(same dial for °C and °F)
Hidden mounting
screws
(no protruding lugs)
Housing and sensor
to mount
in any position
Submersible in
pressurized vessel
(pressure range up
to 21 bar)
Wide range of media
and temperalure
limits (liquid filled
remote sensor)
Standard or custom
length
armoured capillaries
available
Single or dual switch
with weatherproof housing
or explosion proof
enclosures
acc. to ULand
CSAspecifications
Grounding
screw
Terminal strip
labeled
‘C’, ‘NO’ and ‘NC’
SPDT switch
Optional
adjustable
differential
Overload
protection
Amblent
temperature
compensation -
bimetal discs
1,8 m, 3,6 m or 7,5 m
stainless steel or
copper capillary
standard or custom
lengths to suit
Remote sensor and capillary type Local mount type
Outside
liquid fill
Introduction
Pressure - Temperature limit
see „Accessories“ page 16
|
|