Catalogue Mechanical Pressure Switches
www.barksdale.de
print switch display
Page / 60
Barksdale - 145239, 3625, 14130, 141654, 5429, 2155, 3075, 5507
/ 60
See other catalogues for Barksdale
Text version of the page

Diaphragm seal Piston Press. Switches Type E1H-...

Mechanical single switchRepeatability ±2.0 % at constant temperature

Features

Diaphragm seal piston industrial pressure switch,set point can be adjusted with corresponding reference unit during operation

Measuring ranges

-0.28 ... -0.9 bar and 0.1 ... 34 bar

Applications

Machine and tool engineering, Dosing machines, Plant engineering, Sprinkler control

Technical Data

Wetted parts: Electrical connection: Screw terminals and cable gland PG13.5 Diaphragm:Process connection:NBROptional: FKM, PTFE Anodized aluminium Optional: brass, polysulfone, aluminium nickel-plated Repeatability: ±1 % at constant temperature Electrical ratings and hysteresis: A large variety of microswitches offers different electrical ratings and hysteresis for many applications. Switching rate: max. 20/min Weight: E1S-...: approx. 0.35 kg Temperature range: -30 °C... +70 °C Set point adjustment: System of protection IP00 Approval: Intrinsically safe: Overpressure switches:Vacuum switches:Turn the adjustment screw clockwise to increase the set point. Turn the adjustment screw clockwise to decrease the set point. --- The switches are designed for intrinsically safe applications. Please add "Exi" to your ordering details when placing an order. To comply with the intrinsically safe approval following max. ratings must not be exceeded: Umax = 28 V Imax = 50 mA Housing: Without housing for installation in control panels Process connection: Overpressure switches:Vacuum switches (VAC):1/4“ NPT femaleOptional: 1/8“ NPT female + 1/2“ NPT male (P6) G1/4 female (P7)1/4“ NPT female (P4) 1/8“ NPT female +1/2“ NPT male (P6)

Adjustable ranges

Values shown in red (max. increasing pressure) = max. operating pressure Pressure range codeAdjustable range [bar]Proof pressure [bar]Max. hysteresis of switch types in bar (end of range)Increasing press.Decreasing press.(short term)H, GH [bar]M, GM [bar] Overpressure 15 0.10 ... 1,0 0.04 ... 1,0030 / 700.080.080
Specifications are subject to changes without notice.Index: A 90 0.80 ... 6,0 0.20 ... 5,0030 / 700.550.680 250 2.10 ... 17,0 0.70 ... 16,0030 / 701.371.440 500 3.70 ... 34,0 1.72... 32,0030 / 701.932.750Vacuum VAC -0.28 ... -0.9 0.20 ... 0,820,20.080.077

36

Barksdale

DirectIndustry's Virtual Technical Library: PDF Catalogue | Technical Documentation | Brochure | Manual | Industrial directory | Specifications | Characteristics
Search Go
Contents table
page 1 p.1
page 2 p.2
page 3 p.3
page 4 p.4
page 5 p.5
page 6 p.6
page 7 p.7
page 8 p.8
page 9 p.9
page 10 p.10
page 11 p.11
page 12 p.12
page 13 p.13
page 14 p.14
page 15 p.15
page 16 p.16
page 17 p.17
page 18 p.18
page 19 p.19
page 20 p.20
page 21 p.21
page 22 p.22
page 23 p.23
page 24 p.24
page 25 p.25
page 26 p.26
page 27 p.27
page 28 p.28
page 29 p.29
page 30 p.30
page 31 p.31
page 32 p.32
page 33 p.33
page 34 p.34
page 35 p.35
page 36 p.36
page 37 p.37
page 38 p.38
page 39 p.39
page 40 p.40
page 41 p.41
page 42 p.42
page 43 p.43
page 44 p.44
page 45 p.45
page 46 p.46
page 47 p.47
page 48 p.48
page 49 p.49
page 50 p.50
Pages:
1-50
51-60