Catalogue Flow Switches
www.barksdale.de
print switch display
Page / 20
Barksdale - 3621, 68101, 208333, 81699
/ 20
See other catalogues for Barksdale
Text version of the page
for monitoring volume flow of gaseous media, with or without optical display
Features
set point continuously adjustable
rugged, low hysteresis, any mounting position,
high accuracy and functional safety
Measuring ranges
0,2...1,3 Nl/min to 200...650 Nl/min for air
Applications
Measuring and monitoring of gaseous media, e. g. in cooling systems, test beds, pumps etc.
Technical data BFS-10-N-AIR (without indication)
Measuring principle : variable aera flow meter manufacturer
Technical data BFS-10-O-AIR (with optical indication)
Measuring principle : variable aera flow meter
Materials brass version stainless steel ver.
Var. aera flow meter : brass 1.4571
Spring : 1.4571 1.4571
Fitting : brass, nickel-plated 1.4571
Display housing : alumin., anodized alumin., anodized
Glass : Duran 50 Duran 50
Materials Var. aera flow meter : Spring Fitting Housing
brass version stainless steel ver. brass 1.4571
: 1.4571 1.4571
: brass, nickel-plated 1.4571 : brass, nickel-plated 1.4571
: ferrite
ferrite
Operating pressure
brass
VA
Pressure drop
BFS-10-N G1/4
: PN 300 bar
350 bar
0,02...0,2 bar
BFS-10-N G1/2
: PN 300 bar
350 bar
0,02...0,3 bar
BFS-10-N G1
: PN 250 bar
300 bar
0,02...0,4 bar
Magnets
: ferrite
ferrite
Operating pressure brass VA Pressure drop
BFS-10-O G1/4 : PN 16 bar 350 bar 0,02...0,2 bar
BFS-10-O G1/2 : PN 16 bar 350 bar 0,02...0,3 bar
BFS-10-O G1 : PN 10 bar 300 bar 0,02...0,4 bar
Operating temperat. : 100 °C (standard), 160 °C (option HT)
Operating tempérât. : 100 °C (standard), 160 °C (option HT)
Switching ranges (air in Nl/min) for:
Switching ranges (air in Nl/min) for:
BFS-10-N-AIR G1/4:
BFS-10-N-AIR G1/2:
BFS-10-N-AIR G1:
BFS-10-0-AIR G1/4:
BFS-10-0-AIR G1/2:
BFS-10-0-AIR G1:
0,6...2,2
2.5...10
60...180
0,2...1,3
3.0...12
22.5...80
1,7...6,0
5.5...20
100...300
0,5...2,0
7.0...30
50...130
2,5...8,0
8.0...30
200...650
0,8...3,0
12...40
130...420
3.0...12
10...35
1,5...5,0
28...125
200...625
3.0...22
24...90
2,0...8,0
50...200
7.0...24
55...220
3.0...12
100...420
12...34
65...240
3.5...14
120...480
16...56
80...300
5.5...20
20...80
140...525
7.0...24
10...35
-
-
10...42
Accuracy
±10% f. s.
Accuracy : ±10% f. s.
Electrical connect. : plug acc. to DIN 43650
Contact rating BFS-10-N-A1R G1/4 : 200 V / 1 A / 20 VA
200 V / 1 A / 20 VA BFS-10-N-AIR G1/2 : 230 V / 3 A / 60 VA
250 V / 1,5 A / 50 VA BFS-10-N-AIR G1 : 250 V / 3 A / 100 VA
Contact rating
BFS-10-O-AIR G1/4 : 200 V / 1 A / 20 VA (NOJ
200 V / 1 A / 20 VA (SPOT)
BFS-10-O-AIR G1/2 : 230 V / 3 A / 60 VA (NOJ
250 V / 1,5 A / 50 VA (SPOT)
BFS-10-O-AIR G1 : 250 V / 3 A / 100 VA (NOJ
250 V / 1,5 A / 50 VA (SPOT)
EEx-m II T6 vers. : 250 V / 2 A / 60 VA (NOJ G1 only
250 V / 1 A / 30 VA (SPOT) G1 only
Exll 1GD
EEx ia II B T6 vers. : 45 V / 1 A / (NO / SPDT) G1 only
(NO) (SPOT) (NO) (SPOT) (NO) (SPOT)
(NO) G1/2, G1 only (SPOT) G1/2, G1
250 V / 1,5 A / 50 VA
EEx-m II T6 vers.
250 V / 2 A / 60 VA
250 V / 1 A / 30 VA
Exil 1GD
EEx ia II B T6 vers. : 45 V / 1 A / (NO / SPDT) G1/2, G1 only
Protection class
: IP65 (plug acc. to DIN 43650) IP67 (with moulded cable, EEx-models only)
Protection class
: IP65 (plug acc. to DIN 43650) IP67 (with moulded cable, EEx-models only)
DirectIndustry's Virtual Technical Library: PDF Catalogue | Technical Documentation | Brochure | Manual | Industrial directory | Specifications | Characteristics
Search Go
Contents table
page 1 p.1
page 2 p.2
page 3 p.3
page 4 p.4
page 5 p.5
page 6 p.6
page 7 p.7
page 8 p.8
page 9 p.9
page 10 p.10
page 11 p.11
page 12 p.12
page 13 p.13
page 14 p.14
page 15 p.15
page 16 p.16
page 17 p.17
page 18 p.18
page 19 p.19
page 20 p.20