Pressure
ModelUAD 3 - V3
Measuring ranges Display -9999... +9999, Current input 4... 20 mA, Voltage input 0... 10 VDC Output signals 4...20 mA0... 10 VDC Process connection 2 x plug 3-pin, DIN EN 175 301-803-A (prev. DIN 43650)
Electrical connection Screw terminals 16-pin; 1 x PG13.5 side entry Media temperature range --- System of protection IP65 Sensor element --- Features Rugged, universal digital display with two analog inputs, two outputs and 4 relay outputs Applications OEM applications, hydraulic and pneumatic systems,
test bed and apparatus engineering,
heavy industry Linearity error max. <0.2% f. s. Display 2 x 8-digit 14-segment LCD display, digit height 12 mm, red and green, bargraph Switching outputs 4 x switching outputs with SPDT relays, adjustable switching time delay 0... 10 s Hysteresis / Deadband --- Options on request Temperature influence <0.05 % f. s. / 10 K from -10 °C... +70 °C >
Specifications are subject to changes without notice.Index: A Operating temperature range -10 °C... +70 °C (see Technical Data) Power supply 18... 32 V DC >
Barksdale
9