ModelSwitch 2000UDS 7
Measuring ranges 0...1 bar to 0...600 bar gauge-1...0 bar to 0...600 bar gauge0...1 bar 0...10 bar absolute pressure Output signals 4...20 mA 0...10 V DC4...20 mA 0...10 V DC Process connection G1/4 M, stainless steelG1/4 M stainless steel, G1/2 M, flush
Electrical connection Plug M12 x 1, 4-pinPlug M12 x 1, 5-pin Media temperature range -25 °C... +100 °C-25 °C... +100 °C System of protection IP65 IP67 with PG / IP65 with plug Sensor element Piezoresistive silicone measuring cell with internal or flush stainless steel
industrial diaphragm Piezoresistive silicone measuring cell with internal stainless steel diaphragm Linearity error Features max. <0.5% f. s.max. <0.5% f. s. Rugged, compact dual pressure switchRugged, compact dual pressure switch, stainless steel Display 3-digit 7-segment LED display4-digit LED dot-matrix display, digit height 5 mm, green Applications OEM applications, hydraulic systems, plant and steel construction, automobile industry,
machine tool constructionHydraulic and pneumatic systems,
test bed / apparatus construction, automation,
Process / chemical technology Hysteresis / Deadband Switching outputs freely adjustablefreely adjustable 2x solid state outputpnp NO/NC (programmable), adjustable switching time delay 0... 10 s 2x solid state outputpnp NO/NC (programmable), adjustable switching time delay 0... 10 s Options on requestGL, UL approval Temperature influence <0.2 % f. s. / 10 K from -10 °C... +70 °C<0.2 % f. s. / 10 K from -10 °C... +70 °C Operating temperature range -10 °C... +70 °C (see Technical Data)-10 °C... +70 °C (see Technical Data) Power supply 15... 32 V DC18... 32 V DC >
Specifications are subject to changes without notice.Index: A 6
Barksdale