QT50U Series
U-GAGE
® Sensors
QT50U Universal Voltage Specifications
Effective Beam See charts EBPC-1, EBPC-2 and EBPC-3 on page 471. Supply Voltage 85 to 264V ac, 50/60 Hz / 24 to 250V dc (1.5 watts max. exclusive of load) Ultrasonic Frequency 75 kHz, rep. rate 96 milliseconds. Supply Protection Circuitry Protected against transient over voltages. DC hookup is without regard to polarity. Output Protection Protected against short circuit conditions Delay at Power-up 1.5 seconds Output Configuration SPDT (Single-Pole, Double-Throw) electromechanical relay output. One normally open (NO) and one normally closed (NC). Output RatingsMax. switching power (resistive load): 2000 VA, 240 W (1000 VA, 120 W for sensors with Micro QD) Max. switching voltage (resistive load): 250V ac, 125V dc Max. switching current (resistive load): 8A @ 250V ac, 8A @ 30V dc derated to 200 mA @ 125V dc (4A max. for sensors with Micro QD) Min. voltage and current: 5V dc, 10 mA Mechanical life of relay: 50,000,000 operations Electrical life of relay at full resistive load: 100,000 operationsNOTE: Transient suppression is recommended when switching inductive loads. Temperature EffectUncompensated: 0.2% of distance/° C Compensated: 0.02% of distance/° C Repeatability 1.0 mm >
MEASUREMENT & INSPECTION HysteresisWindow-limit sensor models: 5 mm Fill-level control sensor models: 0 mm Output Response Time Selectable 1600, 400 or 100 milliseconds Minimum Window Size 20 mm Adjustments Sensing limits: TEACH-Mode programming of near and far limits may be set using the TEACH push button. Sensor configuration: Output response time and temperature compensation mode may be set using the Speed push button. Factory default settings: 400 milliseconds output response timeTemperature compensation enabled IndicatorsGreen Power On LED: Indicates power is ON Red Signal LED : Indicates target is within sensing range, and the condition of the received signal. Output indicator (bicolor Yellow/Red): Indicates output status or TEACH mode Response indicator (bicolor Yellow/Red): Indicates output response time selection ConstructionTransducer: Ceramic/Epoxy composite Housing: ABS Membrane Switch: Polyester Environmental Rating Leakproof design is rated IEC IP67; NEMA 6P Connections 2 m or 9 m shielded 5-conductor (with
industrial drain) PVC jacketed attached cable, or 5-pin Micro-style quick-disconnect or 5-pin Mini-style quick-disconnect. QD cables are ordered separately. See pages 386 and 388. Operating ConditionsTemperature: -20° to +70° C Relative humidity: 100% Vibration and Mechanical Shock All models meet Mil Std. 202F requirements. Method 201A (vibration: 10 to 60Hz max., double amplitude 0.06", maximum acceleration 10G). Also meets IEC 947-5-2 requirements: 30G 11 milliseconds duration, half sine wave Temperature Warmup Drift Less than 1.0% of sensing distance upon power-up with Temperature Compensation enabled Application Notes Objects passing inside the specified minimum sensing distance (200 mm) may produce a false response Certifications Approvals in process. Contact factory for update. Hookup Diagrams UN05 (p. 488) >
Teflon ® is a registered trademark of Dupont ™ More information online at
bannerengineering.com 289