Q45UR Remote sensors Specifications (cont’d) Q45UR Remote Sensors Specifications
IndicatorsDiscrete: Three status LEDs: Green ON steady: Power to controller is ON Green flashing: Output is overloaded Yellow ON steady: Output are conducting (Yellow also indicates programming status during setup) Red flashing: Relative strength of received echo5-segment moving dot LED indicates the position of the target within the sensing window Analog: Three status LEDs: Green ON steady: Power to controller is ON Green flashing: Current output fault detected (indicates that the 4-20 mA current path to ground has been opened) Yellow ON steady: Target is sensed within the window limits (Yellow LED also indicates programming status during setup mode) Red flashing: Relative strength of received echo5-segment moving dot LED indicates the position of the target within the sensing window ConstructionController: Molded thermoplastic polyester housing, o-ring sealed transparent acrylic top cover, and stainless steel hardware M18C2.0: Stainless steel M18 threaded barrel housing and jam nuts, polyetherimide front cover, ceramic
transducer, polyurethane rear cover Sensors: S18C2.0: Thermoplastic polyester S18 threaded barrel housing and jam nuts, polyetherimide front cover, ceramic transducer, polyurethane rear cover Q13C2.0: Molded 30% glass reinforced thermoplastic polyester housing, ceramic transducer, fully epoxy-encapsulated Environmental RatingController: IEC IP67; NEMA 6P Sensor: IEC IP65; NEMA 4 ConnectionsController: 2 m or 9 m attached cable, or 5-pin Mini-style or Euro-style quick-disconnect fitting. See pages 382 and 388. >
MEASUREMENT & INSPECTION Sensor: 2 m attached PVC cable terminated with 4-pin Euro-style quick-disconnect fitting for connection to controller. Operating ConditionsController and sensor: -25° to +70° C Relative humidity: 85% (non-condensing) Vibration and Mechanical Shock All models meet Mil. Std. 202F requirements. Method 201A Vibration: 10 to 60Hz max., double amplitude 0.06” (maximum acceleration 10G). Method 213B conditions H & I (Shock: 75G with unit operating; 100G for non-
operation). Also meets IEC 947-5-2 requirements: 30G, 11 milliseconds duration, half sine wave. Application NotesDiscrete: The TEACH-mode function of the controller is used to set the sensing distance set point. The sensing window size is set using DIP switches #2 and #3. The sensing distance set point is centered within the sensing widow. The size of the sensing window may be adjusted at any time, with or without power applied, and without re-teaching the sensing distance set point. The controller has non-volatile memory which remembers the last sensing distance set point setting if power is removed and later reapplied. The sensing distance set point may be programmed via the Remote TEACH input (see hookup diagrams). Acceptable target angle is within ±5° of normal for a smooth, flat target; target rotation does affect the apparent target location with respect to the sensor. Analog: The controller has non-volatile memory which remembers the last sensing distance set point setting if power is removed and later reapplied. The sensing distance set point may be programmed via the Remote TEACH input (see hookup diagrams).
Acceptable target angle is within ±5° of normal for a smooth, flat target; target rotation does affect the apparent target location with respect to the sensor. Certifications Hookup DiagramsAnalog Models: MI19 (p. 496) Discrete Models : MI18 (p. 496) >