Catalogue Specialty Sensors
www.bannerengineering.com
print switch display
Page / 28
Make a request   
BANNER - 6073
/ 28
See other catalogues for BANNER
Text version of the page

Opt i cal Buttons

Spec i alty Sensors

STB Self-Checking, 10-30V dc

DownloadPDF

ModelsCable*UpperHousingOutputTypeDataSheet

STBVP6 2 mPolysulfone

PHOTOELECTRICS

STBVP6Q 4-P i n M i n i QD STBVP6Q5 4-P i n Euro QD

ComplementaryPNPSolid-state

64136 STBVP6L 2 mPolycarbonate STBVP6LQ 4-P i n M i n i QD STBVP6LQ5 4-P i n Euro QD

STB Self-Checking, 20-30V ac/dc

Download PDF

ModelsCable*UpperHousingOutputTypeDataSheet

STBVR81 2 mPolysulfone STBVR81Q 5-P i n M i n i QD STBVR81Q6 5-P i n Euro QD

Two IndependentandComplementary e/m Relays

64136 STBVR81L 2 mPolycarbonate STBVR81LQ 5-P i n M i n i QD STBVR81LQ6 5-P i n Euro QD

* For 9 m cable, add suff i x W/30 to the 2 m model number (example, STBVP6 W/30 ) . A model w i th a QD requ i res a mat i ng cable (see pages 382 and 387) .

STB Specifications

Supply Voltage and CurrentSTBVP6 Models: 10 to 30V dc; Power Consumpt i on: approx . 1 . 8 W @ 24V dc (w i th no output load) STBVR81 Models: 20 to 30V ac/dc; Power Consumpt i on: approx . 1 . 8 W/1 . 8 VA @24V ac/dc Supply Protection Circuitry Protected aga i nst trans i ent voltages and reverse polar i ty Output ConfigurationSTBVP6 Models: Complementary PNP (sourc i ng) open collector trans i stors STBVR81 Models: Complementary electromechan i cal relay Output RatingSTBVP6 Models (solid-state outputs): Max. load: 150 mA On-state saturation voltage: ≤ 15V @ full load Off-state leakage current: less than 1 µA STBVR81 Models (electromechanical relay): Max. voltage: 150V dc, 125V ac Max. switching current: 1A Max. resistive load power: 60 VA or 30 W dc Mechanical life of relay: 50,000,000 Electrical life of relay: 150,000 (typ i cally @ 1 . 5 kVA sw i tch i ng power) Output Protection All models protected aga i nst false pulse on power-up . Models w i th sol i d-state outputs have overload and short-c i rcu i t protect i on . Response Time 20 m i ll i seconds ON/OFF Indicators2 green Led indicators:Power: ON – power appl i ed OFF – power off Output/fault: ON – button i s act i vated OFF – button i s deact i vated Flash i ng – i nternal fault or blocked button on power-up detected Construction Totally encapsulated, non-metall i c enclosure . Black polysulfone or red polycarbonate upper hous i ng (see Appl i cat i on Notes, page 229); f i ber-re i nforced PBT polyester base . Electron i cs fully epoxy-encapsulated . Suppl i ed w i th polypropylene (TP) f i eld cover .

228

More i nformat i on onl i ne at

bannereng i neer i ng . com

DirectIndustry's Virtual Technical Library: PDF Catalogue | Technical Documentation | Brochure | Manual | Industrial directory | Specifications | Characteristics
Search Go
Contents table
page 1 p.1
page 2 p.2
page 3 p.3
page 4 p.4
page 5 p.5
page 6 p.6
page 7 p.7
page 8 p.8
page 9 p.9
page 10 p.10
page 11 p.11
page 12 p.12
page 13 p.13
page 14 p.14
page 15 p.15
page 16 p.16
page 17 p.17
page 18 p.18
page 19 p.19
page 20 p.20
page 21 p.21
page 22 p.22
page 23 p.23
page 24 p.24
page 25 p.25
page 26 p.26
page 27 p.27
page 28 p.28
pdf-page pdf di En 2008-10-41-11