SLC1 Series
Specialty Sensors
SLC1, 10-30V dc
u
oc \-
u
LLI
_l
LU
o
o
X
Û.
Models
Slot Width
Cable**
Output Type
Response
User Adjustments
Data Sheet
SLC1BB6 SLC1BB6Q
1 mm
2 m 5-pin Euro QD
Bipolar NPN/PNP
100 us
None Required
59369
For 9 m cable, add suffix W/30 to the 2 m model number (example, SLC1BB6 W/30). A model with a QD requires a mating cable (see page 382).
SLC1 Specifications
Supply Voltage and Current
10 to 30V dc (10% max. ripple) @ less than 60 mA (exclusive of load )
Supply Protection Circuitry
Protected against reverse polarity and transient voltages
Power-Up or Reset Delay
1 second typical (outputs are non-conducting during this time)
Output Configuration
Bipolar: one current-sourcing (PNP) and one current-sinking (NPN) open-collector transistor
Output Rating
150 mA max. (each output)
OFF-state leakage current: less than 5 mA @ 30V dc
Output saturation voltage: less than 1V @ 10 mA dc; less than 1.6V @ 150 mA dc
Output Protection Circuitry
Protected against continuous overload and short-circuit of outputs Overload trip point: > 200 mA, typical, at 20° C
Output Invert Control/Reset
Gray wire has dual functionality, and may be controlled by a PLC Input impedance: 10 Ki>
Outputs ON during gap (turn OFF at leading edge of label): leave open, or connect to 0 to +1V dc
Outputs ON during label (turn ON at leading edge of label): connect to +5 to 30V dc
Microprocessor reset: toggle gray wire to opposite polarity for > 100 milliseconds (see Hookups, page 491)
Registration Accuracy*
±0.3 mm typical, web speeds up to 1.5 m per second
Maximum Web Speed*
10 m per second
Response Time*
100 microseconds
Minimum Sensing Speed*
100 mm per minute
Maximum Switching Speed*
1 kHz
Minimum Gap or Label Size
2 mm
Adjustments
No user adjustments; automatic continuous adjustment of sensing threshold and drift compensation under internal microprocessor control
Adjustment interval: every 250 milliseconds or 4 labels, whichever is greater
Indicators
Two LEDs, green and yellow:
Green ON steady: power to sensor is ON Green flashing @ 4 Hz: output is overloaded Yellow ON steady: NPN and PNP outputs are ON Green and Yellow flashing alternately @ 1 Hz: internal error; reset sensor
Construction
Housings are machined aluminum with black anodized finish
Environmental Rating
IP67; NEMA 6
Connections
2 m or 9 m 5-wire attached cable, or 5-pin Euro-style quick-disconnect fitting; cables for QD models are purchased separately. See page 382.
Operating Conditions
Temperature: +5° to 50° C Relative humidity: 90% at 50° C, non-condensing
Certifications
C€
Hookup Diagrams
SP10 (p. 491)
Based on 3.2 mm gap between labels, and web speeds of up to 10 m per second. Instantaneous web speed, not average web speed, must be used to determine actual operating speeds in stepped-advance label systems.
222 More information online at bannerengineering.ccm
DirectIndustry's Virtual Technical Library: PDF Catalogue | Technical Documentation | Brochure | Manual | Industrial directory | Specifications | Characteristics
Search Go
Contents table
page 1 p.1
page 2 p.2
page 3 p.3
page 4 p.4
page 5 p.5
page 6 p.6
page 7 p.7
page 8 p.8
page 9 p.9
page 10 p.10
page 11 p.11
page 12 p.12
page 13 p.13
page 14 p.14
page 15 p.15
page 16 p.16
page 17 p.17
page 18 p.18
page 19 p.19
page 20 p.20
page 21 p.21
page 22 p.22
page 23 p.23
page 24 p.24
page 25 p.25
page 26 p.26
page 27 p.27
page 28 p.28
pdf-page pdf di En 2008-10-41-12