Catalogue Specialty Sensors
www.bannerengineering.com
print switch display
Page / 28
BANNER - 16679, 82637
/ 28
See other catalogues for BANNER
Text version of the page
SL Series
Specialty Sensors
SLE30 and SLE10 Expert, 10-30V dc (cont'd)
U
ec I-
u
LU _l LU
o
o
X Q.
\1 PDF
Data
Sensing Mode/LED*
Slot Width
Output Type
Response
Repeatability
Sheet
500 us
100 us
58338
150 us
75 us
500 us
100 us
60378
150 us
75 us
Cable**
Models
SLE30B6V SLE30B6VQ
2 m 5-Pin Euro QD
30 mm
SLE30B6VY SLE30B6VYQ
2 m
5-Pin Euro QD
SLOT
Bipolar NPN/PNP
SLE10B6V SLE10B6VQ
2 m
5-Pin Euro QD
IH
10 mm
SLE10B6VY SLE10B6VYQ
2 m
5-Pin Euro QD
SLOT
Visible Red LED
For 9 m cable, add suffix W/30 to the 2 m model number (example, SLE30B6V W/30). A model with a QD requires a mating cable (see page 382).
SLE30 and SLE10 Expert Specifications
Supply Voltage and Current
10 to 30V dc (10% max. ripple) at less than 45 mA, exclusive of load
Supply Protection Circuitry
Protected against reverse polarity and transient voltages
Output Configuration
Bipolar: One current sourcing (PNP) and one current sinking (NPN) open-collector transistor
Output Rating
150 mA max. each output at 25° C, derated to 100 mA at 70° C (derate «1 mA per ° C)
OFF-state leakage current: less than 5 uA @ 30V dc
ON-state saturation current: less than 1V @ 10 mA; less than 1.5V @ 150 mA
Output Protection Circuitry
Protected against false pulse on power-up and continuous overload or short-circuit of outputs
Output Response Time
Sensors will respond to either a "light" or a "dark" signal of 500 microseconds (or 150 microseconds, depending on model) or longer duration, 1 kHz max.
NOTE: 1 second delay on power-up; outputs are non-conducting during this time.
Repeatability
100 microseconds or 75 microseconds, depending on model
Adjustments
Push-button TEACH-mode sensitivity setting; remote TEACH-mode input is provided (gray wire)
Indicators
Two LEDs: Yellow and Bicolor Green/Red
Green (RUN Mode): ON when power is applied
Flashes when received light level approaches the switching threshold Red (TEACH Mode): OFF when no signal is received.
Pulses to indicate signal strength (received light level). Rate is proportional to signal
strength (the stronger the signal, the faster the pulse rate). This is a function of
Banner's patented Alignment Indicating Device (AID™). Alternating Red/Green: Microprocessor memory error Flashing
Yellow (Static TEACH): ON to indicate sensor is ready to learn output ON condition OFF to indicate sensor is ready to learn output OFF condition
Yellow (Dynamic TEACH): Pulses at 0.5 Hz when ready to sample ON to indicate Dynamic TEACH industrial sampling OFF to indicate sampling was accepted
Yellow (RUN Mode): ON when outputs are conducting
Construction
Housing: ABS/polycarbonate Industrial lenses: Acrylic
Environmental Rating
NEMA 6; IEC IP67
Connections
PVC-jacketed 5-conductor 2 m or 9 m unterminated cable, or 5-pin Euro-style quick-disconnect (QD) fitting are available. QD cables are ordered separately. See page 382.
Operating Conditions
Temperature: -20° to +70° C Relative humidity: 90% at 50° C (non-condensing)
Application Notes
The first condition presented during TEACH mode becomes the output ON condition.
Certifications
C€
Hookup Diagrams
DC11 (p. 478)
220 More information online at bannerengineeringxgim
DirectIndustry's Virtual Technical Library: PDF Catalogue | Technical Documentation | Brochure | Manual | Industrial directory | Specifications | Characteristics
Search Go
Contents table
page 1 p.1
page 2 p.2
page 3 p.3
page 4 p.4
page 5 p.5
page 6 p.6
page 7 p.7
page 8 p.8
page 9 p.9
page 10 p.10
page 11 p.11
page 12 p.12
page 13 p.13
page 14 p.14
page 15 p.15
page 16 p.16
page 17 p.17
page 18 p.18
page 19 p.19
page 20 p.20
page 21 p.21
page 22 p.22
page 23 p.23
page 24 p.24
page 25 p.25
page 26 p.26
page 27 p.27
page 28 p.28