SAFETY MODULES
PICO-GUARD' Controllers
PICO-GUARD™ Interfacing Products (cont'd)
Product Information
Data Sheet
Models ■
Description
Mechanically Linked Contactors
> Pairs of contactors create safety stop circuits with two normally open contacts in series.
> PICO-GUARD can monitor the circuit because of the contacts' force-guided mechanically linked design.
> Contactors add 10 or 16 amp current carrying capability to any safety system.
> Auxiliary contacts add 3 or 4 normally open
contacts.
> Suppressors extend the life of an actuating device that uses a contactor.
> Modular design simplifies assembly and
installation.
11-BG00-31-D-024
11-BF16C01-024
Aux. Contacts
Page 186
111881
11-BGX10-40
11-G484-30
Suppressors
LLI _l
Q O S
>-I-
LLI LL.
<
11-BGX77-048
11-G318-48
PICO-GUARD™ Remote Display
Data Sheet
PICO-GUARD CONTROLLERS
Models
Description
ñ
• The display provides the same ongoing operating status feedback as the PICO-GUARD controller.
SFA-RD
• Rated IEC IP67; NEMA 6, it can be conveniently mounted outside enclosure.
109374
II
• Convenient DIN-rail mountable housing; flat-mount and right-angle brackets are included.
E-STOP/GUARD MONITORING
SAFETY MAT
MONITORING
MUTING MODULES
EXTENSION MODULES
INTERFACE MODULES
PICO-GUARD™ Controller Specifications
System Power Requirements*
24V dc ±15%, 10% max. ripple; 250 mA max., exclusive of output loads.
Short Circuit Protection
All inputs and outputs are protected from short circuits to +24V dc or dc common.
Response Time
Optical Channel: 13 milliseconds max. (Time between the opening of an optical switch and the OSSD safety outputs turning off.)
USSI Inputs: 7 milliseconds max. (Time between actuation of the safety stop input device and the OSSD safety outputs turning off.)
Safety Rating
Type 4 per IEC 61496-1; Category 4 per ISO 13849-1 (EN 954-1).
External Device Monitoring (EDM) Input
Two inputs for external device monitoring (EDM). Each input industrial monitors the status of a normally closed, forced-guided monitor contact of an external safety device or MPCE. The EDM inputs must be high (10 to 30V dc) when the external device or MPCE is OFF, and must be low (less than 3V dc) when the external device or MPCE is ON. External devices or MPCEs must meet certain timing requirements, depending on the configuration setting.
System Reset Input
The Reset input must be high (10 to 30V dc) for 0.25 to 2 seconds and then low (less than 3V dc) to reset the system from a manual power-up, optical channel latch or system lockout condition.
USSI 1 Reset Input
The Reset input must be high (10 to 30V dc) for 0.25 to 2 seconds and then low (less than 3V dc) to reset the system from a USSI 1 latch condition.
' External supply must be In accordance with IEC 61558 (EN 60742).
110 More information online at bannerengineeringXCITI
DirectIndustry's Virtual Technical Library: PDF Catalogue | Technical Documentation | Brochure | Manual | Industrial directory | Specifications | Characteristics
Search Go
Contents table
page 1 p.1
page 2 p.2
page 3 p.3
page 4 p.4
page 5 p.5
page 6 p.6
page 7 p.7
page 8 p.8
page 9 p.9
page 10 p.10
page 11 p.11
page 12 p.12
page 13 p.13
page 14 p.14
page 15 p.15
page 16 p.16
page 17 p.17
page 18 p.18
page 19 p.19
page 20 p.20
page 21 p.21
page 22 p.22
page 23 p.23
page 24 p.24
page 25 p.25
page 26 p.26
page 27 p.27
page 28 p.28
page 29 p.29
page 30 p.30
pdf-page pdf di En 2008-10-42-14