SAFETY MODULES
Muting Modules
MM2-TA-12B Muting Module Specifications (cont'd)
Mute Enable Input
When Mute Enable is selected (functional), this input must have +24V dc applied in order to start a mute; opening this input after mute has begun has no effect. If Mute Enable is disabled, this input will be ignored and a mute cycle can occur regardless of the state of the mute enable input. The switching device must be capable of switching 15-30V dc at 10-50 mA.
Override Inputs
The two-channel inputs must be closed within 3 seconds of each other (simultaneity requirement) and held closed during the 10-second Override. To initiate a subsequent Override, open both channels, wait 3 seconds, and then re-close both channels (within 3 seconds). The switching devices must be capable of switching 15-30V dc at 10-50 mA.
Reset Input
Terminals must be closed for a minimum of 0.25 seconds and not more than 2.0 seconds in order to guarantee a reset. The switching device must be capable of switching 15-30V dc at 10-50 mA.
Mounting
4 mounting holes, 5.5 mm dia.
Construction
Housing: Glass-filled Nylon (Black) Connectors manufacturer: Nickel-plated brass All circuitry epoxy-encapsulated
Environmental Rating
NEMA 4, 13; IEC IP65
Connections
1 each 8-pin Mini-style male 1 each 7-pin Mini-style female
8 each 5-pin Euro-style female (4-pin, if earth ground connection is not used)
Vibration Resistance
Vibration:
Frequency range: 10 to 55 Hz Sweep rate: 1 octave/minute
Amplitude: 0.35 mm (interpreted as 0.70 mm peak to peak)
Number of sweeps: 20 sweeps (10 cycles) per axis, for 3 axes (no delay at resonance)
Bump:
Acceleration: 10 g
Duration of pulse: 16 milliseconds
Number of bumps: 1000 +/- 10 for each axis, for 3 axes
Time between bumps: 2 seconds
Operating Conditions
Temperature range: 0° to +50° C Relative humidity: 95% (non-condensing)
Safety Category
Safety Category 2 per EN 954-1
Certifications
For a list of certifications see page 237.
Wiring Diagrams
WD059 (p. 284)
>
TI
m
-<
1 O
a c
r­m
PI CO-GUARD CONTROLLERS
E-STOP/CUARD MONITORING
SAFETY MAT MONITORING
MUT NG MODULES
EXTENSION MODULES
INTERFACE MODULES
More information online at bannerengineeringx^m 127
DirectIndustry's Virtual Technical Library: PDF Catalogue | Technical Documentation | Brochure | Manual | Industrial directory | Specifications | Characteristics
Search Go
Contents table
page 1 p.1
page 2 p.2
page 3 p.3
page 4 p.4
page 5 p.5
page 6 p.6
page 7 p.7
page 8 p.8
page 9 p.9
page 10 p.10
page 11 p.11
page 12 p.12
page 13 p.13
page 14 p.14
page 15 p.15
page 16 p.16
page 17 p.17
page 18 p.18
page 19 p.19
page 20 p.20
page 21 p.21
page 22 p.22
page 23 p.23
page 24 p.24
page 25 p.25
page 26 p.26
page 27 p.27
page 28 p.28
page 29 p.29
page 30 p.30
pdf-page pdf di En 2008-11-47-22