| | MM2-TA-12B Muting Module Specifications (cont'd) | |
| | Mute Enable Input | When Mute Enable is selected (functional), this input must have +24V dc applied in order to start a mute; opening this input after mute has begun has no effect. If Mute Enable is disabled, this input will be ignored and a mute cycle can occur regardless of the state of the mute enable input. The switching device must be capable of switching 15-30V dc at 10-50 mA. | |
| | Override Inputs | The two-channel inputs must be closed within 3 seconds of each other (simultaneity requirement) and held closed during the 10-second Override. To initiate a subsequent Override, open both channels, wait 3 seconds, and then re-close both channels (within 3 seconds). The switching devices must be capable of switching 15-30V dc at 10-50 mA. | |
| | Reset Input | Terminals must be closed for a minimum of 0.25 seconds and not more than 2.0 seconds in order to guarantee a reset. The switching device must be capable of switching 15-30V dc at 10-50 mA. | |
| | Mounting | 4 mounting holes, 5.5 mm dia. | |
| | Construction | | |
| | Environmental Rating | NEMA 4, 13; IEC IP65 | |
| | Connections | 1 each 8-pin Mini-style male 1 each 7-pin Mini-style female 8 each 5-pin Euro-style female (4-pin, if earth ground connection is not used) | |
| | Vibration Resistance | Vibration: Frequency range: 10 to 55 Hz Sweep rate: 1 octave/minute Amplitude: 0.35 mm (interpreted as 0.70 mm peak to peak) Number of sweeps: 20 sweeps (10 cycles) per axis, for 3 axes (no delay at resonance) Bump: Acceleration: 10 g Duration of pulse: 16 milliseconds Number of bumps: 1000 +/- 10 for each axis, for 3 axes Time between bumps: 2 seconds | |
| | Operating Conditions | Temperature range: 0° to +50° C Relative humidity: 95% (non-condensing) | |
| | Safety Category | Safety Category 2 per EN 954-1 | |
| | Certifications | For a list of certifications see page 237. | |
| | Wiring Diagrams | WD059 (p. 284) | |
| | | | |