ModelSafety CategoryInput DeviceSupply VoltageInputsSafety OutputsOutputRatingAux. OutputsOutput Response TimeData Sheet

MM-TA-12B 4Mechanical&Solid State24V dc2 NC Muteable 63517

(dual)

& 2 NC USSI

2 PNP OSSD

0.5 amps1 PNP10 ms

(dual)

MM2-TA-12B 21 PNP 123894 MMD-TA-12B

2 PNP OSSD

0.5 amps1 PNP10 ms

(dual)

2 or 4Mechanical&Solid State24V dc2 NC Muteable & 2 NC SSI 116390

(dual)

MMD-TA-11B

2 NO

6 amp1 NC30 ms

NC = Normally Closed Relay, NO = Normally Open Relay

MM-TA-12B Muting Module Specifications

Supply Voltage and Current +24V dc ±15% @ 400 mA max (not including draw of the MSSI power, AUX, ML, M1-M4 and OSSD connections)
SAFETY MODULES PICO-GUARDCONTROLLERS Supply Protection Circuitry All inputs and outputs are protected from short circuit to +24V dc or dc common. Output Response Time Muteable Safety Stop Interfaces (MSSI) and the Universal Safety Stop Interfaces (USSI) are less than or equal to 10 milliseconds.
E-STOP/GUARDMONITORING Safety OutputsTwo diverse-redundant solid-state safety outputs: 24V dc, 0.5A sourcing OSSD (output signal switching device). Compatible with Banner “Safety Handshake” protocol.
SAFETY MATMONITORING ON-State voltage: ≥ V in-1.5V dc
MUTINGMODULES Max. leakage current: 1.2 mA; inclusive of faults (including open 0V dc wire) OFF-State voltage: 1.2V dc max.
EXTENSIONMODULES Max. load capacitance: 0.1 µF Non-safety auxiliary output: PNP solid-state output, rated at +24V dc @ 250 mA.
INTERFACEMODULES OSSD test pulse width: 100 to 300 microseconds OSSD test pulse period: 12 microseconds MSSI Power connections +24V dc ±15% @ 2.5A max. output (dependent on System power input). Resettable 2.5A industrial fuse Status Indicators3 Status Indicator LEDs (Red, Green and Yellow): indicate Power ON/OFF, operating mode, lockout, override, and OSSD status Green LEDs adjacent to individual inputs/interfaces indicate status (ON = active/closed) Diagnostic Code Display Diagnostic Display is a two-digit numeric display that indicates the cause of lockout conditions and the amount of time, in seconds, remaining for the backdoor timer. Muting Lamp Output A monitored or non-monitored (selectable) sinking output. If monitoring has been selected, the current draw must be 10 mA to 360 mA. Interconnect wire resistance < 30 . Max. switching voltage: 30V dc Max. switching current: 360 mA Min. switching current: 10 mA Saturation voltage: ≤ 1.5V dc @ 10 mA; ≤ 5V dc @ 360 mA Controls and AdjustmentsAll configured on two redundant banks of DIP switches: Manual/auto reset One-way/two-way muting Monitored/non-monitored mute lamp output One-channel/two-channel/no EDM Backdoor timer Mute on power-up enable Mute enable functional/disabled

124

More information online at

bannerengineering.com

DirectIndustry's Virtual Technical Library: PDF Catalogue | Technical Documentation | Brochure | Manual | Industrial directory | Specifications | Characteristics
Search Go
Contents table
page 1 p.1
page 2 p.2
page 3 p.3
page 4 p.4
page 5 p.5
page 6 p.6
page 7 p.7
page 8 p.8
page 9 p.9
page 10 p.10
page 11 p.11
page 12 p.12
page 13 p.13
page 14 p.14
page 15 p.15
page 16 p.16
page 17 p.17
page 18 p.18
page 19 p.19
page 20 p.20
page 21 p.21
page 22 p.22
page 23 p.23
page 24 p.24
page 25 p.25
page 26 p.26
page 27 p.27
page 28 p.28
page 29 p.29
page 30 p.30
pdf-page pdf di En 2008-11-47-22