| | SAFETY MODULES | |
| | E-Stop and Guard Monitoring Modules | |
| | ES-FA-6G Safety Module Specifications | |
| | Supply Voltage and Current | 24V ac/dc, +/- 10%; 50/60Hz Power consumption: approx. 2 W/0.75 VA | |
| | Supply Protection Circuitry | Protected against transient voltages and reverse polarity | |
| | Output Configuration | Outputs (K1& K2): three redundant (total of six) safety relay (forced-guided) contacts - AgSnO2 one auxiliary non-safety monitor output (open when both K1 and K2 are energized; closed when either K1 or K2 are de-energized) Contact ratings: Max. voltage: 250V ac or 250V dc Max. current: 6 A ac or dc Min. current: 30 mA @ 10V dc Max. power: 1500 VA, 150 W Mechanical life: 10,000,000 operations Electrical life: 100,000 at full resistive load NOTE: Transient suppression is recommended when switching inductive loads. Install suppressors across load. Never install suppressors across output contacts. | |
| | Output Response Time | 35 milliseconds typical | |
| | Input Requirements | Input switch must have a normally closed contact capable of switching 40 to 100 mA @ 13 to 27V ac/dc. Reset switch must have one normally open contact capable of switching 20 to 30 mA @ 13 to 27V ac/dc. | |
| | Status Indicators | Power ON K1 energized K2 energized | |
| | Construction | Polycarbonate | |
| | Environmental Rating | Rated NEMA 1; IEC IP40, Terminals IP20 | |
| | Mounting | Mounts to standard 35 mm DIN rail track. Safety Module must be installed inside an enclosure rated NEMA 3 (IEC IP54), or better. | |
| | Vibration Resistance | 10 to 55Hz @ 0.35 mm displacement per IEC 68-2-6 | |
| | Operating Conditions | Temperature: 0° to +50° C Relative humidity: 90% @ +50° C (non-condensing) | |
| | Certifications | For a list of certifications see page 237. | |
| | Wiring Diagrams | 1-Channel: WD054 (p. 281) | |
| | | | |