Catalogue Safety Modules
www.bannerengineering.com
print switch display
Page / 30
Where to buy
this product ?
Request
a Quote
BANNER - 6073, 2113
/ 30
See other catalogues for BANNER
Text version of the page

SAFETY MODULES

E-Stop and Guard Monitoring Modules

ES-TN-14H.. Safety Module Specifications

Supply Voltage and Current 24V dc, ±20% Power consumption: approx. 5 W Supply Protection Circuitry Protected against transient voltages and reverse polarity Output ConfigurationOutputs K1 & K2: four redundant (total of eight) safety relay (forced-guided) contacts – AgNi, gold flashed one auxiliary normally closed contact – AgNi, gold flashed Outputs K3 & K4: four redundant (total of eight) delayed relay (forced-guided) contacts – AgNi, gold flashed one auxiliary normally closed contact – AgNi, gold flashed Max. voltage: 250V ac or dc Contact ratings (all normally open and normally closed output contacts): Max. current: 4 A ac or dc Min. current: 30 mA @ 24V dc Max. power: 1000 VA, 100 W Mechanical life: 50,000,000 operations Electrical life: 100,000 at full resistive load NOTE: Transient suppression is recommended when switching inductive loads. Install suppressors across load. Never install suppressors across output contacts.Output Response TimeK1 & K2: 50 milliseconds typical K3 & K4 (ES-TN-14H5): 0, 0.5, 1, 2, 4, 6, 8, 10, 15, 20 seconds K3 & K4 (ES-TN-14H6): 0, 5, 10, 20, 30, 50, 70, 100, 150, 200 seconds Delayed Output Timing Tolerance: Set time ±100 milliseconds or ±2%, whichever is greater Input RequirementsInput switch must have a normally closed contact capable of switching 20 mA @ 24V dc. Reset switch must have one normally open contact capable of switching 20 mA @ 24V dc.NOTE: Inputs must be voltage-free, dry contacts.
SAFETY MODULES ON-Time Delay ≥ 100 milliseconds; Time from the E-stop contacts to close (Auto Reset) or the Reset button to open (Manual Reset) and the safety outputs to close
PICO-GUARDCONTROLLERS Status Indicators6 green Led indicators: Construction Polycarbonate housing 1 red LED indicator:
E-STOP/GUARDMONITORING Power Monitor Fault E-Stop Out (K1 &K2 ON/OFF) Reset Timed-Out (K3 & K4 ON/OFF) Environmental Rating Rated NEMA 1; IEC IP40, Terminals IP20, max. terminal torque 0.8 Nm
SAFETY MATMONITORING Mounting Mounts to standard 35 mm DIN rail track. Safety Module must be installed inside an enclosure rated NEMA 3 or IEC IP54, or better.
MUTINGMODULES Vibration Resistance 10 to 55Hz @ 0.35 mm displacement per IEC 68-2-6
EXTENSIONMODULES Operating ConditionsTemperature: 0° to +50° C Relative humidity: 90% @ +50° C (non-condensing)
INTERFACEMODULES Certifications For a list of certifications see page 237. Wiring Diagrams2-Channel: WD053 (p. 280)

118

More information online at

bannerengineering.com

DirectIndustry's Virtual Technical Library: PDF Catalogue | Technical Documentation | Brochure | Manual | Industrial directory | Specifications | Characteristics
Search Go
Contents table
page 1 p.1
page 2 p.2
page 3 p.3
page 4 p.4
page 5 p.5
page 6 p.6
page 7 p.7
page 8 p.8
page 9 p.9
page 10 p.10
page 11 p.11
page 12 p.12
page 13 p.13
page 14 p.14
page 15 p.15
page 16 p.16
page 17 p.17
page 18 p.18
page 19 p.19
page 20 p.20
page 21 p.21
page 22 p.22
page 23 p.23
page 24 p.24
page 25 p.25
page 26 p.26
page 27 p.27
page 28 p.28
page 29 p.29
page 30 p.30
pdf-page pdf di En 2008-12-49-04