SAFETY MODULES

E-Stop and Guard Monitoring Modules

GM-FA-10J Guard Monitoring Module Specifications

Supply Voltage and Current 24V ac/dc ± 20% Power consumption: approx. 3 VA / 3 W Supply Protection Circuitry Protected against transient voltages and reverse polarity Output Configuration Each normally open output channel is a series connection of contacts from two forced-guided (mechanically linked) industrial relays, K1-K2. Contacts: AgNi, 5 µm gold-plated Low Current Rating: Caution: The 5 µm gold-plated contacts allow the switching of low current/low voltage. To preserve the gold plating on the contacts, do not exceed the following max. values at any time: Min. voltage: 1V ac/dc Max. voltage: 60V Min. current: 5 mA ac/dc Max. current: 300 mA Min. power: 5 mW (5 mVA) Max. power: 7 W (7 VA) High Current Rating: If higher loads must be switched through one or more of the contacts, the minimum and maximum values of the contact(s) changes to: Min. voltage: 15V ac/dc Max. voltage: 250V ac/dc Min. current: 30 mA ac/dc Max. current: 6 A Min. power: 5 W (5 VA) Max. power: 200 W (1,500 VA) Mechanical life: 50,000,000 operations Electrical life: 150,000 cycles typical, @ 200 W (1,500 VA) switched power, resistive load Note: Transient suppression is recommended when switching inductive loads. Install suppressors across load. Never install suppressors across output contacts.Output Response Time
SAFETY MODULES 35 milliseconds
PICO-GUARDCONTROLLERS Input RequirementsInput switch must have a normally closed contact and a normally open contact capable of switching 5 to 50 mA @ 15 to 30 V dc.
E-STOP/GUARDMONITORING Reset switch must have one normally open contact capable of switching 5 to 50 mA @ 15 to 30V dc. Max. external resistance between terminals S11/S12, S11/S13, S21/S22 and S21/S23: 270
SAFETY MATMONITORING each. Simultaneity Monitoring2-Channel operation: 3 seconds
MUTINGMODULES 1-Channel operation: infinite Status Indicators4 green LEDs: 1 red LED: Construction Polycarbonate housing
EXTENSIONMODULES Environmental Rating Power: power is supplied to Safety Module Fault Channel 1: inputs satisfied (guard closed) Channel 2: inputs satisfied (guard closed) Output: K1 and K2 energized, safety outputs closed Rated NEMA 1; IEC IP40, Terminals IP20
INTERFACEMODULES Mounting Mounts to standard 35 mm DIN rail track. Safety Module must be installed inside an enclosure rated NEMA 3 (IEC IP54), or better. Vibration Resistance 10 to 55 Hz @ 0.35 mm displacement per IEC 68-2-6 Operating ConditionsTemperature: 0° to +50° C Relative humidity: 90% @ +50° C (non-condensing) Safety Category 4 per ISO 13849-1 (EN954-1) (depending on application) Certifications For a list of certifications see page 237. Wiring Diagrams1-Channel Coded Magnet Switches: WD043 (p. 271) 2-Channel Positive Opening Switches: WD044 (p. 271) 1-Channel (Multiple Guards): WD045 (p. 272) 2-Channel (Multiple Guards): WD046 (p. 272) Guarded Machine: WD047 (p. 274)

114

More information online at

bannerengineering.com

DirectIndustry's Virtual Technical Library: PDF Catalogue | Technical Documentation | Brochure | Manual | Industrial directory | Specifications | Characteristics
Search Go
Contents table
page 1 p.1
page 2 p.2
page 3 p.3
page 4 p.4
page 5 p.5
page 6 p.6
page 7 p.7
page 8 p.8
page 9 p.9
page 10 p.10
page 11 p.11
page 12 p.12
page 13 p.13
page 14 p.14
page 15 p.15
page 16 p.16
page 17 p.17
page 18 p.18
page 19 p.19
page 20 p.20
page 21 p.21
page 22 p.22
page 23 p.23
page 24 p.24
page 25 p.25
page 26 p.26
page 27 p.27
page 28 p.28
page 29 p.29
page 30 p.30