SAFETY LIGHT SCREENS
MICRO-SCREEN
® Systems
MICRO-SCREEN MICRO-SCREEN
® >
DIN Module with DeviceNet
® >
DIN Module with DeviceNet
™ >
Specifications (cont’d)
™ >
Specifications
SAFETYLIGHT SCREENS DeviceNet >
™ ConfigurationVendor Code 12 (Banner Engineering Corp.) Device Type 130 (Safety Light Screen) 1 Product Code
USDINT-1T2D/USDINT-1T4D USDINT-2T2D/USDINT-2T4D 2 USDINT-1L2D/USDINT-1L4D 3 USDINT-2L2D/USDINT-2L4D 4 Connection Types Supported Explicit Message, Poll, Change of State Network Address 0-63 (Manual Switches or Network configured) >
EZ-SCREEN ® Baud Rate Supported Autobaud or Network configured (125K, 250K, 500K) (Factory setting is Autobaud ON) 130_1_2.eds >
PICO-GUARD ™ EDS File Names
USDINT-1T2D/USDINT-1T4D USDINT-2T2D/USDINT-2T4D 130_2_2.eds USDINT-1L2D/USDINT-1L4D 130_3_1.eds >
MICRO-SCREEN ® USDINT-2L2D/USDINT-2L4D 130_4_1.eds Bit Map Icon File Name 130.bmpEDS and Bitmap files on 3.5” floppy disk supplied with controller (p/n >
MINI-SCREEN ® EZ-SCREEN ® TYPE 2 52243 ) Poll and COS I/O Assembly Instances The MICRO-SCREEN device I/O assemblies consist of:• Poll: COS: One product specific input assembly containing operating mode, status of defined area, status of output relays, status of inputs (Key Reset, Test, and E-Stop), noise detected, number of sensor beams, number of beams blocked, Auto Power-up switch settings, COS trigger setting, autobaud setting, floating blanking switch settings and number of fixed beams (Fixed Blanking models only).• One product-specific input assembly containing the operating mode and defined area status. Auxiliary Monitor Relay
Reed relay; 125V ac or dc max., 500 mA max. (10 VA max., resistive load) Safety Outputs Forced-guided contact relays (resistive load).FSD1 & 2, SSD = 250V ac max., 4 amps max. Mechanical life: 10,000,000 operations (minimum). Electrical life (at full rated load): Note: Controllers with model suffix “2” have two FSD output contacts and those with model suffix “4” have four FSD output contacts. 100,000 operations (typical). Arc suppression is recommended when switching inductive loads. EnclosureMaterial: gray polycarbonate, clear polycarbonate cover Rating: NEMA 1; IP20 Operating ConditionsTemperature: 0° to +50° C Relative humidity: 95% maximum (non-condensing) FMEA Tested Per requirements IEC 61496-1 Application Notes Use of fixed blanking requires sensors with 16 or more light beams. Up to 12 beams or 30% of the total number of beams in the array may be blanked, whichever is less. Call factory for applications assistance if a greater number of blanked beams is required. Certifications For a list of certifications see page 236. Wiring Diagrams2 FSDs, 1 SSD and Power Monitoring: WD019 (p. 256) 2 FSDs, 1 SSD and 1-Channel
EDM: WD020 (p. 256) 4 FSDs, 1 SSD and Power Monitoring: WD021 (p. 257) >
DeviceNet ™ is a trademark of Rockwell Automation. More information online at
bannerengineering.com 57