Catalogue Safety Light Screens
www.bannerengineering.com
print switch display
Page / 68
BANNER - 4457, 208510
/ 68
See other catalogues for BANNER
Text version of the page

SAFETY LIGHT SCREENS

MICRO-SCREEN

®

Systems

MICRO-SCREEN MICRO-SCREEN

®

DIN Module with DeviceNet

®

DIN Module with DeviceNet


Specifications (cont’d)


Specifications

SAFETYLIGHT SCREENS DeviceNet
ConfigurationVendor Code 12 (Banner Engineering Corp.) Device Type 130 (Safety Light Screen) 1 Product Code USDINT-1T2D/USDINT-1T4D USDINT-2T2D/USDINT-2T4D 2 USDINT-1L2D/USDINT-1L4D 3 USDINT-2L2D/USDINT-2L4D 4 Connection Types Supported Explicit Message, Poll, Change of State Network Address 0-63 (Manual Switches or Network configured)
EZ-SCREEN ® Baud Rate Supported Autobaud or Network configured (125K, 250K, 500K) (Factory setting is Autobaud ON) 130_1_2.eds
PICO-GUARD EDS File Names USDINT-1T2D/USDINT-1T4D USDINT-2T2D/USDINT-2T4D 130_2_2.eds USDINT-1L2D/USDINT-1L4D 130_3_1.eds
MICRO-SCREEN ® USDINT-2L2D/USDINT-2L4D 130_4_1.eds Bit Map Icon File Name 130.bmpEDS and Bitmap files on 3.5” floppy disk supplied with controller (p/n
MINI-SCREEN ® EZ-SCREEN ® TYPE 2 52243 ) Poll and COS I/O Assembly Instances The MICRO-SCREEN device I/O assemblies consist of:• Poll: COS: One product specific input assembly containing operating mode, status of defined area, status of output relays, status of inputs (Key Reset, Test, and E-Stop), noise detected, number of sensor beams, number of beams blocked, Auto Power-up switch settings, COS trigger setting, autobaud setting, floating blanking switch settings and number of fixed beams (Fixed Blanking models only).• One product-specific input assembly containing the operating mode and defined area status. Auxiliary Monitor Relay Reed relay; 125V ac or dc max., 500 mA max. (10 VA max., resistive load) Safety Outputs Forced-guided contact relays (resistive load).FSD1 & 2, SSD = 250V ac max., 4 amps max. Mechanical life: 10,000,000 operations (minimum). Electrical life (at full rated load): Note: Controllers with model suffix “2” have two FSD output contacts and those with model suffix “4” have four FSD output contacts. 100,000 operations (typical). Arc suppression is recommended when switching inductive loads. EnclosureMaterial: gray polycarbonate, clear polycarbonate cover Rating: NEMA 1; IP20 Operating ConditionsTemperature: 0° to +50° C Relative humidity: 95% maximum (non-condensing) FMEA Tested Per requirements IEC 61496-1 Application Notes Use of fixed blanking requires sensors with 16 or more light beams. Up to 12 beams or 30% of the total number of beams in the array may be blanked, whichever is less. Call factory for applications assistance if a greater number of blanked beams is required. Certifications For a list of certifications see page 236. Wiring Diagrams2 FSDs, 1 SSD and Power Monitoring: WD019 (p. 256) 2 FSDs, 1 SSD and 1-Channel EDM: WD020 (p. 256) 4 FSDs, 1 SSD and Power Monitoring: WD021 (p. 257)
DeviceNet is a trademark of Rockwell Automation.

More information online at

bannerengineering.com 57

DirectIndustry's Virtual Technical Library: PDF Catalogue | Technical Documentation | Brochure | Manual | Industrial directory | Specifications | Characteristics
Search Go
Contents table
page 1 p.1
page 2 p.2
page 3 p.3
page 4 p.4
page 5 p.5
page 6 p.6
page 7 p.7
page 8 p.8
page 9 p.9
page 10 p.10
page 11 p.11
page 12 p.12
page 13 p.13
page 14 p.14
page 15 p.15
page 16 p.16
page 17 p.17
page 18 p.18
page 19 p.19
page 20 p.20
page 21 p.21
page 22 p.22
page 23 p.23
page 24 p.24
page 25 p.25
page 26 p.26
page 27 p.27
page 28 p.28
page 29 p.29
page 30 p.30
page 31 p.31
page 32 p.32
page 33 p.33
page 34 p.34
page 35 p.35
page 36 p.36
page 37 p.37
page 38 p.38
page 39 p.39
page 40 p.40
page 41 p.41
page 42 p.42
page 43 p.43
page 44 p.44
page 45 p.45
page 46 p.46
page 47 p.47
page 48 p.48
page 49 p.49
page 50 p.50
Pages:
1-50
51-68