| | T30 DC Specifications | |
| | Supply Voltage and Current | 10 to 30V dc (10% max. ripple); Supply current (exclusive of load current): Opposed Mode Industrial emitters: 25 mA Opposed Mode Receivers: 20 mA Polarized Retroreflective: 30 mA Fixed-field: 35 mA | |
| | Supply Protection Circuitry | Protected against reverse polarity and transient voltages | |
| | Output Configuration | SPDT solid-state Dc switch; Three-wire hookup; Choose light operate (LO) or dark operate (DO) models; Light operate: Output conducts when the sensor sees its own (or the emitter's) modulated light Dark operate: Output conducts when sensor sees dark | |
| | Output Rating | 150 mA max. (each) in standard hookup; When wired for alarm output, the total load may not exceed 150 mA; Off-state leakage current: less than 1 mA at 30V dc On-state saturation voltage: less than 1V at 10 mA dc; less than 1.5V at 150 mA dc | |
| | Output Protection Circuitry | Protected against false pulse on power-up and continuous overload or short circuit of outputs | |
| | Output Response Time | Opposed: 3 milliseconds ON, 1.5 milliseconds OFF Polarized Retroreflective and Fixed-field: 3 milliseconds ON/OFF NOTE: 100 millisecond delay on power-up; outputs are non-conducting during this time | |
| | Repeatability | Opposed Mode: 2 milliseconds Polarized Retroreflective, Non-polarized Retroreflective, Fixed-field, and Diffuse: 4 milliseconds. Repeatability and response are independent of signal strength. | |
| | Indicators | Two LEDs: Green and Yellow Green ON steady: power to sensor is ON Green flashing: output is overloaded (dc models only) Yellow ON stead: Light operate (LO) output is energized Yellow flashing: excess gain marginal (1-1.5x) in light condition, LO output is energized | |
| | Construction | Housings are thermoplastic polyester. Lenses are polycarbonate or acrylic; one jam nut included. | |
| | Environmental Rating | Leakproof design rated NEMA 6P; DIN 40050 (IP69K) | |
| | Connections | 2 m or 9 m attached cable, or 4-pin Euro-style quick-disconnect fitting. QD cables are ordered separately. See page 380. | |
| | Operating Conditions | Temperature: -40° to +70° C Relative humidity: 90% at 50° C (non-condensing) | |
| | Vibration and Mechanical Shock | All models meet Mil. Std. 202F requirements. Method 201A (Vibration; frequency 10 to 60 Hz, max., double amplitude 0.06-inch acceleration 10G). Method 213B conditions H&I (Shock: 75G with unit operating; 100G for non-operation) | |
| | Certifications | C€ ® ^» LISTED | |
| | Hookup Diagrams | Emitters: DC03 (p. 476) NPN Models: DC07 (p. 477) PNP Models: DC08 (p. 477) | |
| | | | |