Catalogue Midsize Sensors
www.bannerengineering.com
print switch display
Page / 32
BANNER - 6224, 145291, 81437
/ 32
See other catalogues for BANNER
Text version of the page
T30 Series
Midsize Sensors
T30, 20-250V ac (cont'd) (flfe
Download
Models
Sensing Mode/LED*
Range
Cable**
Output Type
Excess Gain
Beam Pattern
Data
Sheet
T30AW3FF200 T30AW3FF200Q1
0
- 200 mm
2 m
4-Pin Micro QD
LO
EGCF-27
T30RW3FF200 T30RW3FF200Q1
Cutoff
2 m
4-Pin Micro QD
DO
(p. 442)
T30AW3FF400 T30AW3FF400Q1
' ■
i
0
- 400 mm
2 m
4-Pin Micro QD
LO
EGCF-28
116162
T30RW3FF400 T30RW3FF400Q1
FL
)<=
XED-FIEl
_D
Ä
Cutoff
2 m
4-Pin Micro QD
DO
(p. 442)
T30AW3FF600 T30AW3FF600Q1
0
- 600 mm
2 m
4-Pin Micro QD
LO
EGCF-29
T30RW3FF600 T30RW3FF600Q1
Cutoff
2 m
4-Pin Micro QD
DO
(p. 442)
For 9 m cable, add W/30 to the 2 m model number (example, T30AW3FF200 W/30). A QD model requires a mating cable (see page 386).
T30 DC Specifications
Supply Voltage and Current
10 to 30V dc (10% max. ripple); Supply current (exclusive of load current): Opposed Mode Industrial emitters: 25 mA Opposed Mode Receivers: 20 mA Polarized Retroreflective: 30 mA Fixed-field: 35 mA
Supply Protection Circuitry
Protected against reverse polarity and transient voltages
Output Configuration
SPDT solid-state Dc switch; Three-wire hookup; Choose light operate (LO) or dark operate (DO) models; Light operate: Output conducts when the sensor sees its own (or the emitter's) modulated light Dark operate: Output conducts when sensor sees dark
Output Rating
150 mA max. (each) in standard hookup; When wired for alarm output, the total load may not exceed 150 mA; Off-state leakage current: less than 1 mA at 30V dc
On-state saturation voltage: less than 1V at 10 mA dc; less than 1.5V at 150 mA dc
Output Protection Circuitry
Protected against false pulse on power-up and continuous overload or short circuit of outputs
Output Response Time
Opposed: 3 milliseconds ON, 1.5 milliseconds OFF
Polarized Retroreflective and Fixed-field: 3 milliseconds ON/OFF
NOTE: 100 millisecond delay on power-up; outputs are non-conducting during this time
Repeatability
Opposed Mode: 2 milliseconds
Polarized Retroreflective, Non-polarized Retroreflective, Fixed-field, and Diffuse: 4 milliseconds. Repeatability and response are independent of signal strength.
Indicators
Two LEDs: Green and Yellow
Green ON steady: power to sensor is ON
Green flashing: output is overloaded (dc models only)
Yellow ON stead: Light operate (LO) output is energized
Yellow flashing: excess gain marginal (1-1.5x) in light condition, LO output is energized
Construction
Housings are thermoplastic polyester. Lenses are polycarbonate or acrylic; one jam nut included.
Environmental Rating
Leakproof design rated NEMA 6P; DIN 40050 (IP69K)
Connections
2 m or 9 m attached cable, or 4-pin Euro-style quick-disconnect fitting. QD cables are ordered separately. See page 380.
Operating Conditions
Temperature: -40° to +70° C Relative humidity: 90% at 50° C (non-condensing)
Vibration and
Mechanical Shock
All models meet Mil. Std. 202F requirements. Method 201A (Vibration; frequency 10 to 60 Hz, max., double amplitude 0.06-inch acceleration 10G). Method 213B conditions H&I (Shock: 75G with unit operating; 100G for non-operation)
Certifications
C€ ®
^» LISTED
Hookup Diagrams
Emitters: DC03 (p. 476) NPN Models: DC07 (p. 477) PNP Models: DC08 (p. 477)
More information online at bannerengineering.cfjHTi 125
DirectIndustry's Virtual Technical Library: PDF Catalogue | Technical Documentation | Brochure | Manual | Industrial directory | Specifications | Characteristics
Search Go
Contents table
page 1 p.1
page 2 p.2
page 3 p.3
page 4 p.4
page 5 p.5
page 6 p.6
page 7 p.7
page 8 p.8
page 9 p.9
page 10 p.10
page 11 p.11
page 12 p.12
page 13 p.13
page 14 p.14
page 15 p.15
page 16 p.16
page 17 p.17
page 18 p.18
page 19 p.19
page 20 p.20
page 21 p.21
page 22 p.22
page 23 p.23
page 24 p.24
page 25 p.25
page 26 p.26
page 27 p.27
page 28 p.28
page 29 p.29
page 30 p.30
page 31 p.31
page 32 p.32