Catalogue Measuring Light Screens
www.bannerengineering.com
print switch display
Page / 17
Make a request   
BANNER -
/ 17
See other catalogues for BANNER
Text version of the page

MINI-ARRAY

®

Series

A-GAGE

®

Sensors

MINI-ARRAY MINI-ARRAY

®

Controller Specifications (cont’d)

®

Controller Specifications (cont’d)

Construction Polycarbonate Environmental Rating NEMA 1; IP20 Operating ConditionsTemperature: -20° to +70° C Relative humidity: 95% (non-condensing) Certifications
R R

MINI-ARRAY

®

Controller with DeviceNet


Specifications

DeviceNet ConfigurationsVendor code: 12 (Banner Corp.) Device type: 110 Product code: 1 (MACNXDN-1) 2 (MACPXDN-1) Connection types supported: Explicit Message, Poll, COS Network address: 0-63 (network configured), default = 63 Baud rate supported: 125K, 250K, 500K (network configured), default = 125K Output ConfigurationsMACPXDN-1: Two PNP discrete (switched) MACNXDN-1: Two NPN discrete (switched) Power Requirements*Controller, emitter and receiver: 16 to 30V dc @ 1.2 A max. (typical: 0.5 A @ 16V dc) DeviceNet Power* 11 to 25V dc - supplied by DeviceNet BUS Network InputsSensor input: Emitter and receiver wire in parallel to five terminals. Trigger (Gate) input: Optically isolated, requires 10 to 30V dc (7.5 k impedance) for gate signal Discrete OutputsNPN outputs: Open collector NPN transistor rated at 30V dc max., 150 mA max. PNP outputs: Open collector PNP transistor rated at 30V dc max., 150 mA max. All discrete outputs: OFF-state leakage current: less than 10 µA @ 30V dc ON-state saturation voltage: less than 1V @ 10 mA and < 1.5V @ 150 mA System Programming Via DeviceNet interface and supplied EDS files.
MEASUREMENT & INSPECTION System Status IndicatorsOutput (steady red): Output #1 energized. Alarm (flashing red): Output #2 energized. Gate (steady red): Trigger (Gate) input status. Alignment (steady green): Proper emitter/receiver alignment and a clear, unblocked light screen(ON) when green or green/yellow receiver LEDs are ON. Diag 1 (green), Diag 2 (red), Diag 3 (red): Used in combination to display System status Network Status IndicatorBicolored (red/green) LED visible on the control module front panel indicates network status:Steady Green: On-line, connected to master Flashing Green: On-line, address and baud rate OK Steady Red: Critical network fault or duplicate node address detected Flashing Red: Connection timeout OFF: No network power or off-line Construction Polycarbonate housing; mounts to flat surface or directly onto 35-mm DIN rail Environmental Rating NEMA 1; IP20 Operating ConditionsTemperature: -20° to +70° C Relative humidity: 95% @ 50° C (non-condensing) *Application Note The controller must be powered up before the DeviceNet connection in every power-up situation for proper operation
DeviceNet is a trademark of the Open DeviceNet Vendor Association, Inc.

316

More information online at

bannerengineering.com

DirectIndustry's Virtual Technical Library: PDF Catalogue | Technical Documentation | Brochure | Manual | Industrial directory | Specifications | Characteristics
Search Go
Contents table
page 1 p.1
page 2 p.2
page 3 p.3
page 4 p.4
page 5 p.5
page 6 p.6
page 7 p.7
page 8 p.8
page 9 p.9
page 10 p.10
page 11 p.11
page 12 p.12
page 13 p.13
page 14 p.14
page 15 p.15
page 16 p.16
page 17 p.17
pdf-page pdf di En 2008-10-42-15