Catalogue Light Gauging Sensors
www.bannerengineering.com
print switch display
Page / 18
BANNER -
/ 18
See other catalogues for BANNER
Text version of the page

LG Series

L-GAGE

®

Sensors

LG5 and LG10 Specifications (cont’d) LG5 and LG10 Specifications

Temperature EffectLG5: +/- 7 µm/° C LG10: +/- 25 µm/° C Remote TEACH and Laser Control Input Impedance 18 k min. (65 k min. at 5V dc) Remote TEACHTo teach: Connect yellow wire to +5 to 30V dc To disable: Connect yellow wire to 0 to +2V dc (or open connection) AdjustmentsResponse speed: Push button toggles between Slow, Medium, and Fast (see Output Response Time) Window limits (analog or discrete): TEACH-mode programming of near and far window limits. Limits may also be taught remotely Analog output slope: The first limit taught is assigned to the minimum analog output (0V dc or 4 mA). Laser ControlTo enable laser: Connect green wire to +5 to 30V dc To disable laser: Connect green wire to 0 to +2V dc (or open connection)250 millisecond delay upon enable/disable IndicatorsGreen Power ON LED: Indicates when power is ON, overloaded output and laser status. Yellow Output LED: Indicates when discrete load output is conducting. Red Signal LED: Indicates when target is within sensing range and the condition of the received light signal. Tri-color Red/Green/Yellow TEACH LED: Indicates sensor is ready for programming each limit (indicates red for analog output, green for discrete, and yellow for simultaneous analog and discrete.) Yellow Fast/Slow LEDs: Combination of 2 lights ON or OFF indicates 1 of 3 response speeds ConstructionHousing: Zinc alloy die-cast, plated and painted finish Cover plate: aluminum with painted finish Lens: acrylic Environmental Rating IP67; NEMA 6
MEASUREMENT & INSPECTION Connections 2 m or 9 m 7-conductor shielded PVC-jacketed attached cable, or 150 mm 8-pin Euro-style pigtail quick-disconnect. Mating QD cables are purchased separately. See page 384. Operating ConditionsTemperature: -10° to +50° C Relative humidity: 90% at 50° C, non-condensing Vibration andMechanical ShockVibration: 60 Hz, 30 minutes, 3 axes Shock: 30G for 11 milliseconds, half sine wave, 3 axes Application Notes For comparison, a white ceramic test surface has approximately 91% of the reflectivity of a white Kodak test card with a matte finish. A dark gray ceramic test surface has approximately 11% of the reflectivity of a white Kodak test card with a matte finish. (Allow 15-minute warm-up for maximum linearity.) Certifications Hookup DiagramsNPN Models: MI05 (p. 493) PNP Models: MI06 (p. 493)

More information online at

bannerengineering.com 279

DirectIndustry's Virtual Technical Library: PDF Catalogue | Technical Documentation | Brochure | Manual | Industrial directory | Specifications | Characteristics
Search Go
Contents table
page 1 p.1
page 2 p.2
page 3 p.3
page 4 p.4
page 5 p.5
page 6 p.6
page 7 p.7
page 8 p.8
page 9 p.9
page 10 p.10
page 11 p.11
page 12 p.12
page 13 p.13
page 14 p.14
page 15 p.15
page 16 p.16
page 17 p.17
page 18 p.18