Q60 Series
Fullsize Sensors
PHOTOELECTRICS Q60 Specifications
Supply Voltage and CurrentQ60BB6AF and Q60BB6AFV models: 10 to 30V dc (10% max. ripple) at less than 50 mA exclusive of load Q60BB6LAF models: 10 to 30V dc (10% max. ripple) at less than 35 mA exclusive of load Q60VR3LAF and Q60VR3AFV Universal models: 12 to 250V dc or 24 to 250V ac, 50/60 HzInput power 1.5 W max. Supply Protection Circuitry Protected against reverse polarity and transient voltages(Q60VR3 models’ dc hookup is without regard to polarity) Output ConfigurationQ60BB6AF, Q60BB6AFV and Q60BB6LAF models: Bipolar: one NPN (current sinking) and one PNP (current sourcing) open-collector transistor Q60VR3AF, Q60VR3LAF and Q60VR3AFV cabled models: E/M Relay (SPDT), normally closed and normally open contacts Q60VR3AFQ1, Q60VR3AFVQ1 and Q60VR3LAFQ1 (QD) models: E/M Relay (SPST), normally open contact Output RatingDC models: 150 mA max. each output @ 25C Off-state leakage current: less than 5 µA @ 30V dc Output saturation NPN: less than 200 mV @ 10 mA and less than 1V @ 150 mA Output saturation PNP: less than 1V at 10 mA; less than 1.5V at 150 mA Universal Voltage models:Min. voltage and current: 5V dc, 10 mA Mechanical life of relay: 50,000,000 operations Electrical life of relay at full resistive load: 100,000 operations Max. switching power (resistive load): Cabled models: 1250VA, 150 W QD models: 750VA, 90W Max. switching voltage (resistive load): Cabled models: 5 A @ 250V ac, 5 A @ 30V dc derated to 200 mA @ 125V dc Cabled models: 250V ac, 125V dc QD models: 250V ac, 125V dc Max. switching current (resistive load): QD models: 3 A @ 250V ac, 3 A @ 30V dc derated to 200 mA @ 125V dc Output Protection CircuitryQ60BB6AF, Q60BB6LAF and Q60BB6AFV models: Protected against continuous overload or short circuit of outputs All models: Protected against false pulse on power-up Output Response TimeQ60BB6AF, Q60BB6LAF and Q60BB6AFV models: 2 milliseconds ON/OFF Q60VR3AF, Q60VR3LAF and Q60VR3AFV Universal models: 15 milliseconds ON/OFFNOTE: 150 millisecond delay on power-up (Q60BB6LAF has 1 second max. delay at power-up); outputs do no conduct during this time. Repeatability 500 microseconds Sensing Hysteresis For Infrared models, see chart HC-3; for Visible Red models, see chart HC-4, and for Laser models, see chart HC-2, all on page 470.
2000 mm cutoff - less than 3% of set cutoff distance
1600 mm cutoff - less than 2.25% of set cutoff distance
1200 mm cutoff - less than 1.30% of set cutoff distance800 mm cutoff - less than 0.5% of set cutoff distance400 mm cutoff - less than 0.25% of set cutoff distance Adjustments 2 momentary push buttons: [ON Delay (+) an OFF Delay (-)] ON Delay select: 8 milliseconds to 16 seconds LO/DO select OFF Delay select: 8 milliseconds to 16 seconds Push button lockout for securitySlotted, geared, 2-turn, cutoff range adjustment screw (mechanical stops on both ends of travel) Indicators Q60AF and Q60AFV models:ON Delay Green ON Steady: Run mode, ON delay is active Green Flashing: ON Delay Selection mode is active OFF Delay Green ON Steady: Run mode, OFF delay is active Green Flashing: OFF Delay Selection mode is active >
Note: outputs are activeduring on/off timing
selection mode. 5-Segment Light Bar*: Indicates relative delay time during ON or OFF Delay Selection modes Output Amber ON Steady: Outputs are conducting Green ON Steady: During ON/OFF Delay Selection modes Dark Operate Green ON Steady: Dark Operate is selected Lockout Green ON Steady: Buttons are locked out Light Operate Green ON Steady: Light Operate is selected Signal Green ON Steady: Sensor is receiving signal Green Flashing: Marginal signal (1.0 to 2.25 excess gain) * Output, Dark Operate, Lockout, Light Operate and Signal indicators function as 5-Segment Light Bar during ON or OFF Delay Selection modes >
More information online at
bannerengineering.com 161