R55F Series

Fiber Systems

PHOTOELECTRICS

R55 Fiber Optic Specifications

Supply Voltage and Current 10 to 30V dc (10% max. ripple) at less than 70 mA, exclusive of load Supply Protection Circuitry Protected against reverse polarity and transient voltages Output ConfigurationBipolar: One current sourcing (PNP) and one current sinking (NPN) open-collector transistor Output Rating 150 mA max each output @ 25° C (derate 1 mA per ° C increase) OFF-state leakage current: less than 5 µA @ 30V dc ON-state saturation voltage: PNP Output less than 1V @ 10 mA and 1.5V @ 150 mA NPN Output less than 200 mV @ 10 mA and 1V @ 150 mA SETUP Mode: OFF — no delay RUN Mode: OFF — no delay Flashing — 20 milliseconds delay ON — 20 or 40 milliseconds Delay ON — 40 milliseconds delay Output Protection Circuitry Indicators Construction Protected against false pulse on power-up and continuous overload or short-circuit of outputs 10-segment (green) light bar indicates signal strengthLight Operate (green) Dark Operate (green) Outputs Conducting (yellow) OFF Delay (green): Black ABS/polycarbonate blend; nylon fiber clip mounts to standard 35 mm DIN rail1 stainless steel right angle bracket and 1 PBT polyester bracket for mounting to flat surfaces also included with sensor Output Response Time 50 microsecondsNOTE: 100 millisecond delay on power-up; outputs do not conduct during this time. Environmental Rating Using Remote TEACH input (gray wire): Dynamic TEACH (teach on-the-fly) sensitivity adjustment Static TEACH sensitivity adjustment Static Single-Point TEACH Light operate/Dark operate OFF Delay select: 0 milliseconds, 20 milliseconds or 40 milliseconds Push button lockout for security IEC IP67; NEMA 6 AdjustmentsUsing push buttons (“+” Dynamic and “-” Static): Connections 2 m or 9 m PVC-jacketed 5-conductor cable or 5-pin Euro-style quick-disconnect (QD) fitting. QD cables are ordered separately. See page 382. Manually adjust Switch Point using “+” or “-” buttons Dynamic TEACH (teach on-the-fly) sensitivity adjustment Static TEACH sensitivity adjustment Static Single-Point TEACH Light operate/Dark operate OFF Delay select: 0 milliseconds, 20 milliseconds or 40 milliseconds Fibers: Fiber clip (no tool required) Operating ConditionsTemperature: -10° to +55° C Relative humidity: 90% at 50° C (non-condensing) Application Notes • Do not mount the fiber tip directly perpendicular to shiny surfaces; position it at approximately a 15° angle in relation to the sensing target.• Minimize web or product “flutter” whenever possible to maximize sensing reliability. Certifications Hookup Diagrams DC11 (p. 478)

More information online at

bannerengineering.com 179

DirectIndustry's Virtual Technical Library: PDF Catalogue | Technical Documentation | Brochure | Manual | Industrial directory | Specifications | Characteristics
Search Go
Contents table
page 1 p.1
page 2 p.2
page 3 p.3
page 4 p.4
page 5 p.5
page 6 p.6
page 7 p.7
page 8 p.8
page 9 p.9
page 10 p.10
page 11 p.11
page 12 p.12
page 13 p.13
page 14 p.14
page 15 p.15
page 16 p.16
page 17 p.17
page 18 p.18
page 19 p.19
page 20 p.20
page 21 p.21
page 22 p.22
page 23 p.23
page 24 p.24
page 25 p.25
page 26 p.26
page 27 p.27
page 28 p.28
page 29 p.29
page 30 p.30
page 31 p.31
page 32 p.32
page 33 p.33
page 34 p.34
page 35 p.35
page 36 p.36
page 37 p.37
page 38 p.38
page 39 p.39
page 40 p.40
page 41 p.41
page 42 p.42
pdf-page pdf di En 2008-10-41-12