| | Supply Voltage and Current | 24V ac/dc ±15% at 150 mA | |
| | Supply Protection Circuitry | Protected against transient voltages and reverse polarity (dc hookup is without regard to polarity) | |
| | Output Configuration | Outputs (K1 and K2): two redundant (total of four) forced-guided safety relay contacts Contact ratings: Maximum voltage: 250V ac or 250V dc Maximum current: 6A ac or dc (resistive load) Maximum power: 1500 VA, 150 watts Mechanical life: 50,000,000 operations Electrical life: 150,000 cycles (typically @ 1.5 kVA switching power) NOTE: Transient suppression is recommended when switching inductive loads. Install suppressors across load. Never install suppressors across output contacts. | |
| | Output Response Time | 35 milliseconds maximum ON/OFF | |
| | Input Requirements | Outputs from both hand controls (1 N.O. and 1 N.C.) must each be capable of switching 10 to 50 mA @ 18 to 30V dc. | |
| | Simultaneity Monitoring Period | <500 milliseconds | |
| | Status Indicators | Power ON Fault Input 1 energized Input 2 energized Output | |
| | Housing | Polycarbonate. Rated NEMA 1 (IEC IP20) | |
| | Mounting | Mounts to standard 35 mm DIN rail track. Safety modules must be installed inside an enclosure rated NEMA 3 (IEC IP54), or better. | |
| | Vibration Resistance | 10 to 55Hz @ 0.35 mm displacement per IEC 68-2-6 | |
| | Operating Conditions | Temperature: 0° to +50°C (+32° to 122°F) Maximum Relative Humidity: 90% @ +50°C (non-condensing) | |
| | Dimensions | See dimension drawing below. | |
| | Safety Category | 4 per EN 954-1; Type IIIC per EN 574 | |
| | Certifications | Approvals in process. Contact factory for more information. | |
| | | | |