WORLD-BEAM
® QS18 Series
Compact Sensors
WORLD-BEAM WORLD-BEAM
® >
QS18 Specifications (cont’d)
® >
QS18 Specifications
PHOTOELECTRICS Sensing Hysteresis*Retroreflective Laser models: 12% of range typical Diffuse Laser models: 15% of range typical Adjustable-field models: 0.5% of range typical at 20 mm cutoff 1% of range typical at 50 mm cutoff 3% of range typical at 100 mm cutoff Adjustable-field Laser models: 1% range typical at 30 mm cutoff 2% range typical at 75 mm cutoff
5% range typical at 150 mm cutoff Adjustments*Retroreflective, Retroreflective Laser, Convergent, Diffuse, Diffuse Laser and Glass Fiber Optic, Plastic Fiber Optic models: Single-turn sensitivity (Gain) adjustment
potentiometer Adjustable-field models: five-turn adjustment screw sets cutoff distance between 20 and 100 mm (adjustable-field) or 30 and 150 mm (laser adjustable-field), clutched at both ends of travel IndicatorsLaser Emitter models: Green LED: Power applied All other models, 2
Led indicators: Green ON steady: Power ON Green flashing: Output overloaded Yellow >
† ON steady: Light sensed Yellow >
† flashing: Marginal excess gain (1.0 to 1.5x excess gain) in the light condition >
† NOTE: Prior to date code 0223, the output indicator was red instead of yellow.Construction ABS housing, rated IEC IP67; NEMA 6; acrylic lens cover (Laser Emitter models have PMMA window)2.5 mm (adjustable-field only) and 3 mm mounting hardware included Connections 2 m or 9 m 4-wire PVC cable, or 4-pin 150 mm pigtail Pico-style QD ( Q ), or 4-pin 150 mm pigtail Euro-style QD ( Q5 ), or 4-pin Integral Pico-style QD ( Q7 ), or 4-pin Integral Euro-style QD ( Q8 ), depending on model. See pages 378 and 380. Operating Conditions Laser models Adjustable-field All othersTemperature: -10° to +50° C 0° to +55° C -20° to +70° C Relative humidity: 90% @ 50° C (non-condensing) Laser Classification Class 1 laser product; complies with EN60825-1: 2001 and 21 CFR 1040.10, except deviations persuant to Laser Notice 50, dated 7-26-01. >
(Laser models only) CertificationsLaser models: All other models: Hookup DiagramsEmitters: DC03 (p. 476) NPN Models: DC04 (p.476) PNP Models: DC05 (p. 477) Laser Emitter Models : SP01 (p. 489) >
* Does not apply to laser emitter models. Industrial lasers that are safe under reasonably foreseeable conditions of operation, including the use of optical instruments for intrabeam viewing.
Reference 60825-1 Amend. 2 © IEC:2001(E),
section 8.2.
For safe laser use:
• Do not permit a person to stare at the laser from within the beam.• Do not point the laser at a person’s eye at close range.
• Locate open laser beam paths either above or below eye level, where practical. More information online at
bannerengineering.com 71