Catalogue Accessories (safety)
www.bannerengineering.com
print switch display
Page / 54
Where to buy
this product ?
Request
a Quote
BANNER - 6072, 143345, 81203
/ 54
See other catalogues for BANNER
Text version of the page
ACCESSORIES
Cables & Wiring Products
r
AC Interface Box Specifications
Input Voltage and Current
100-230V ac ±15%; 16.8W max., output 24V dc 0.7A
Input current: typ. 0.37A @ 100V ac in typ. 0.23A @ 200V ac in Inrush current: typ. 15A @ 100V ac in (5 milliseconds max.)
typ. 30A @ 200V ac in (5 milliseconds max.)
Output Voltage and Current
24V dc @ 0.7 A (16.8 W)
SELV; capable of buffering 20 milliseconds power interruptions
Supply Protection Circuitry
Protected against transient voltages
Output Configuration
Models EZAC-R.. only; see models listing on previous page.
Each normally open output channel is a series connection of contacts from two forced-guided (positive-guided) industrial relays, K1-K2. The normally closed contact is a parallel connection of contacts from K1-K2.
Contacts: AgNi, 5 urn gold-plated
Low Current Rating:
Caution: The 5 pm gold-plated contacts allow the switching of low current/low voltage.
To preserve the gold plating on the contacts, the following max. values should not be exceeded at any time:
Min. voltage: 1V ac/dc Min. current: 5 mA ac/dc Min. power: 5 mW (5 mVA)
Max. voltage: 60V ac/dc Max. current: 300 mA Max. power: 7 W (7 VA)
High Current Rating:
If higher loads must be switched through one or more of the contacts, the minimum and maximum values of
the contact(s) changes to:
Min. voltage: 15V ac/dc Max. voltage: 250V ac/dc
Min. current: 30 mA ac/dc Max. current: 8 A
Min. power: 5 W (5 VA) Max. power: 200 W (2000 VA)
Mechanical life: 50,000,000 operations
Electrical life: 100,000 operations (typical @ 200 W [2000 VA] switched power, resistive load)
Feedback Contact Rating (Y1-Y2, Y3-Y4):
Min. voltage: 1V ac/dc Max. voltage: 60V ac/dc
Min. current: 5 mA ac/dc Max. current: 300 mA
Min. power: 5 mW (5 mVA) Max. power: 7 W (7 VA)
NOTE: Transient suppression is recommended when switching inductive loads. Install suppressors across load. Never install suppressors across output contacts.
CABLES & WIRING
BRACKETS
CORNER MIRRORS
Output Response Time
10 milliseconds max.
STANDS
Status Indicators
Models EZAC-R.. : One bicolor (Red/Green) Led indicator on box cover indicates the power and output status of internal relays K1 and K2.
Models EZAC-E.. : One Green LED indicator on box cover indicates the power status (ON when power is ON).
HARSH DUTY SOLUTIONS
Construction
Welded steel box with yellow polyester powder paint finish
REPLACEMENT PARTS
Environmental Rating
IEC IP65
Vibration Resistance
10 to 50 Hz @ 0.35 mm displacement per IEC 68-2-6
Mounting
Box provides flanges for screw mounting; can be mounted directly to EZ-SCREEN receiver or emitter housing.
Operating Conditions
Temperature: 0° to +55° C
Relative humidity: 90% @ +55° C (non-condensing)
Application Notes
The box offers a field-replaceable relay module; see Repairs section of data sheet for more information.
Certifications
Approvals are in process.
Wiring Diagrams
EZAC-R9QE8: WD009 (p. 250) EZAC-R11-QE8: WD010 (p. 251) EZAC-R15A-QE8-QS83: WD011 (p. 252) EZAC-R8N-QE8-QS53: WD012 (p. 252) EZAC-R10N-QE8-QS53: WD013 (p. 253) EZAC-E-QE8/QE5: WD014 (p. 253)
More information online at bannerengineeringx&nri 185
DirectIndustry's Virtual Technical Library: PDF Catalogue | Technical Documentation | Brochure | Manual | Industrial directory | Specifications | Characteristics
Search Go
Contents table
page 1 p.1
page 2 p.2
page 3 p.3
page 4 p.4
page 5 p.5
page 6 p.6
page 7 p.7
page 8 p.8
page 9 p.9
page 10 p.10
page 11 p.11
page 12 p.12
page 13 p.13
page 14 p.14
page 15 p.15
page 16 p.16
page 17 p.17
page 18 p.18
page 19 p.19
page 20 p.20
page 21 p.21
page 22 p.22
page 23 p.23
page 24 p.24
page 25 p.25
page 26 p.26
page 27 p.27
page 28 p.28
page 29 p.29
page 30 p.30
page 31 p.31
page 32 p.32
page 33 p.33
page 34 p.34
page 35 p.35
page 36 p.36
page 37 p.37
page 38 p.38
page 39 p.39
page 40 p.40
page 41 p.41
page 42 p.42
page 43 p.43
page 44 p.44
page 45 p.45
page 46 p.46
page 47 p.47
page 48 p.48
page 49 p.49
page 50 p.50
Pages:
1-50
51-54
pdf-page pdf di En 2008-11-47-23