Wireless Solutions - BANNER ENGINEERING - #2

/ 2


catalogue search
P. 01
P. 02
Pages:


See other catalogues for BANNER ENGINEERING

Text version of the page
t DX80 Star Topology DX85 Extension I/O DX70 Point to Point DX80 2,4 GHz Gateways with Modbus RTU (RS485) Communication & Nodes Gateway Model Antenna Type Discrete I/O Analogue I/O Node Model IN (PNP) OUT (PNP) IN OUT Type DX80G2M6W8P4 Internal 8 4 / / / DX80N2X6W8P4 DX80G2M6S8P4 External 8 4 / / / DX80N2X6S8P4 DX80G2M6W4P8 Internal 4 8 / / / DX80N2X6W4P8 DX80G2M6S4P8 External 4 8 / / / DX80N2X6S4P8 DX80G2M6W6P6 Internal 6 6 / / / DX80N2X6W6P6 DX80G2M6S6P6 External 6 6 / / / DX80N2X6S6P6 DX80G2M6W4P4M2M2 Internal 4 4 2 2 0-20 mA DX80N2X6W4P4M2M2 DX80G2M6S4P4M2M2 External 4 4 2 2 0-20 mA DX80N2X6S4P4M2M2 DX80G2M6W4P4V2V2 Internal 4 4 2 2 0-10 VDC DX80N2X6W4P4V2V2 DX80G2M6S4P4V2V2 External 4 4 2 2 0-10 VDC DX80N2X6S4P4V2V2 DX80G2M6W0P0M4M4 Internal / / 4 4 0-20 mA DX80N2X6W0P0M4M4 DX80G2M6S0P0M4M4 External / / 4 4 0-20 mA DX80N2X6S0P0M4M4 DX80G2M6W0P0V4V4 Internal / / 4 4 0-10 VDC DX80N2X6W0P0V4V4 DX80G2M6S0P0V4V4 External / / 4 4 0-10 VDC DX80N2X6S0P0V4V4 DX85 Remote I/O Extension Unit (only for Gateways with Modbus RTU Communication) Model Discrete I/O Analogue I/O IN (PNP) OUT (PNP) IN OUT Type DX85M8P4 8 4 / / / DX85M4P8 4 8 / / / DX85M6P6 6 6 / / / DX85M4P4M2M2 4 4 2 2 0-20 mA DX85M0P0M4M4 / / 4 4 0-20 mA DX80 2,4 GHz Special FlexPower Nodes - Counter Model Antenna Type Discrete I/O Special I/O IN (NPN) OUT (NMOS) IN Type Note DX80N2X2W4A2 Internal 2 (NPN-PNP) 2 2 Frequency DX80N2X2S4A2 External 2 (NPN-PNP) 2 2 Frequency DX80N2X1W2A1 Internal 1 (NPN-PNP) 1 1 Frequency Internal Battery DX80N2X1S2A1 External 1 (NPN-PNP) 1 1 Frequency Internal Battery DX80 2,4 GHz Special FlexPower Nodes - Temperature & Humidity DX80N2X2W2S Internal 2 2 2 Serial Input DX80N2X2S2S External 2 2 2 Serial Input DX80N2X1W1S Internal 1 1 1 Serial Input Internal Battery DX80N2X1S1S External 1 1 1 Serial Input Internal Battery DX80 2,4 GHz Special FlexPower Nodes - K50 EZ-LIGHT DX80N2X1W1K3 Internal 1 3 / / Internal Battery DX80N2X1S1K3 External 1 3 / / Internal Battery DX81 FlexPower Supply Model Description DX81 1 battery DX81P6 6 batteries DX81H 1 battery for DX99 DX70 2,4 GHz Gateways & Nodes Gateway Model Antenna Type Discrete I/O Analogue I/O IN OUT IN OUT Type DX70G2X6W4P4M2M2 Internal 4 4 2 2 0-20 mA DX70G2X6S4P4M2M2 External 4 4 2 2 0-20 mA DX70G2X6W4P8 Internal 4 8 / / / DX70G2X6S4P8 External 4 8 / / / Node Model Antenna Type Discrete I/O Analogue I/O IN OUT IN OUT Type DX70N2X6W4P4M2M2 Internal 4 4 2 2 0-20 mA DX70N2X6S4P4M2M2 External 4 4 2 2 0-20 mA DX70N2X6W8P4 Internal 8 4 / / / DX70N2X6S8P4 External 8 4 / / / Connectors for DX70 Top & Bottom 1/2-inch NPT Hub Entrance Model Description BWA-QD5.5 M12 connector 5-pin BWA-QD8.5 M12 connector 8-pin BWA-QD12.5 M12 connector 12-pin BWA-CG.5-10 Cable Glands (10 pieces) DX80 2,4 GHz Model Antenna Type Description DX80P2T6S External Gateway Pro with Modbus TCP & Ethernet IP Communication (no I/O) DX80P2S6S External Gateway Pro with CoDeSys Programming Capability only DX80DR2M External Data Radio - 100 mW with RS232 or RS485 Communication DX80GM2S External FlexPower Gateway with only Modbus RTU (RS485) Communication (no I/O) DX80 2,4 GHz FlexPower Nodes Model Antenna Type Discrete I/O Analogue I/O IN (NPN) OUT (NMOS) IN OUT Type DX80N2X2W4N4 Internal 4 4 / / / DX80N2X2S4N4 External 4 4 / / / DX80N2X2W2N2M2 Internal 2 (NPN-PNP) 2 2 / 0-20 mA (Switch configurable) DX80N2X2S2N2M2 External 2 (NPN-PNP) 2 2 / 0-20 mA (Switch configurable) DX80N2X2W2N2M4 Internal 2 2 4 / 0-20 mA DX80N2X2S2N2M4 External 2 2 4 / 0-20 mA DX80 2,4 GHz Special FlexPower Nodes - Temperature DX80N2X2W2N2T Internal 2 2 3 / Thermocouple DX80N2X2S2N2T External 2 2 3 / Thermocouple DX80N2X2W0P0R Internal / / 4 / PT100 (RTD) (3 wires) DX80N2X2S0P0R External / / 4 / PT100 (RTD) (3 wires) Accessories DX80 FlexPower Nodes DX80 GATEWAY PRO DATA RADIO and FlexPower Gateway Accessories Antennas Model Description BWA-2O2-C 2dBi antenna indoor RP-SMA Male BWA-2O5-C 5dBi antenna indoor RP-SMA Male BWA-2O7-C 7dBi antenna indoor RP-SMA Male BWA-2O6-A 6dBi antenna outdoor N Female BWA-2O8-A 8,5dBi antenna outdoor N Female DX80 FlexSensors DX81 FlexPower Supply DX99 2,4 GHz for Hazardous Locations Model Antenna Type Discrete IN (2)* Analogue IN (2)* Power Housing DX99N2X1S2N0M2X0B1 External PNP or NPN 0-20 mA Internal Battery Metal DX99N2X2S2N0M2X0A1 External PNP or NPN 0-20 mA No Internal Battery Plastic DX99N2X2W2N0M2X0A1 Internal PNP or NPN 0-20 mA No Internal Battery Plastic DX99N2X1S2N0V2X0B1 External PNP or NPN 0-10 Vdc Internal Battery Metal DX99N2X2S2N0V2X0A1 External PNP or NPN 0-10 Vdc No Internal Battery Plastic DX99N2X2W2N0V2X0A1 Internal PNP or NPN 0-10 Vdc No Internal Battery Plastic DX99 Intrinsically Safe Nodes FlexSensors Model Description M12FTH1Q Serial Temp/RH sensor calibrated +/-2% M12FTH2Q Serial Temp/RH sensor calibrated +/-3.5% K50LFGRY1Q Serial K50 EZ-LIGHT (3 colour) K50FGYPB1Q Serial K50 EZ-LIGHT (Pushbutton) QT50U-75390 QT50U low power ultrasonic SM312LPQD-76885 Low power mini-beam 3.6 - 5V Retro SM312DQD-75904 Low power mini-beam 3.6 - 5V Diffuse Surge Suppressors Model Description BWC-LMRSFRPB Bulkhead, RP-SMA Type BWC-LFNMN N-Type BWC-LFNBMN Bulkhead, N-Type Convertor cable for the User Configuration Tool BWA-HW-006 RS-485 to USB adapter, 1 m Cables Model Description RP-SMA to RP-SMAF Bulkhead (RG58 cable loss: 1,05 dB/m) BWC-1MRSFRSB4 4 m cable BWC-1MRSFRSB2 2 m cable BWC-1MRSFRSB1 1 m cable BWC-1MRSFRSB0.2 0,2 m cable RP-SMA to N Male (LMR200 cable loss: 0,56 dB/m) BWC-1MRSMN05 0,5 m cable BWC-1MRSMN2 2 m cable N Male to N Female (LMR400 coaxial, cable loss:0,22 dB/m) BWC-4MNFN6 6 m cable BWC-4MNFN15 15 m cable BWC-4MNFN30 30 m cable BWC-4MNFN3 3 m cable Configuration tool ANTENNAS Indoor Outdoor N-Type SURGE SUPPRESSOR CABLES Bulkhead, N-Type N Male to N Female RP-SMA to RP-SMAF Bulkhead The User Configuration Tool uses a USB to RS-485 converter to connect a standard SureCross Gateway to a USB connection on a computer. Once connected, the User Configuration Tool will configure the one to one I/O linking and system polling Bulkhead & RP-SMA RP-SMA to N Male parameters of the wireless system. SENSORS VISION WIRELESS I/O INDICATORS SAFETY Banner offers a full range of sensing solutions DX99 types are ATEX certified for Gas zone 0, and Dust zone 20. *other input types available (thermistor, RTD, Bridge,...) E-A122 - 09/2008 Rev A Solar Panel Model Description BWA-SOLAR-001 Solar Panel Kit BWA-BATT-003 Replacement rechargeable battery pack Banner Engineering europe WWW.BANEREurope.COm Solar Panel

pageCatalog pdf di En 2012-05-22-28