You may also be interested in
Laser emitter, Distance sensor, Safety light curtain, LED indicator, Fiber optic switch
Text version of the page
Q45U SeriesU-GAGE®SensorsUltrasonic Sensors - 7106 Q45U Specifications (cont’d) Q45U SpecificationsConnections 2 m or 9 m attached cable, or 5-pin Mini-style or 5-pin Euro-style QD fitting. QD cables are ordered separately. See pages 382 and 388. Operating ConditionsTemperature: -25° to +70° C Relative humidity: 100% Vibration and Mechanical Shock All models meet Mil. Std. 202F requirements. Method 201A (Vibration: 10 to 60Hz max., double amplitude 0.06", maximum acceleration 10G). Method 213B conditions H & I (Shock: 75G with unit operating; 100G for non-operation) Also meets IEC 947-5-2 requirements: 30G, 11 milliseconds duration, half sine wave. Application NotesShort Range: Min. target size: 10 x 10 mm aluminum plate at 500 mm 35 x 35 mm aluminum plate at 1.4 m Long Range: Min. target size: 50 x 50 mm aluminum plate at 3 m Discrete: Enable/Disable; Connect yellow wire to +5 to 24V dc to enable sensor and 0 to +2V dc to disable sensor. When the sensor is disabled, the last output state is held until the sensor is re-enabled. The wire must be held to the appropriate voltage for at least 40 milliseconds for the sensor to enable or disable. Certifications Hookup DiagramsAnalog Models: MI19 (p. 496) Discrete Models : MI18 (p. 496)MEASUREMENT & INSPECTION More information online atbannerengineering.com 303 |
|