You may also be interested in
Amplifier, Safety switch, Safety light curtain, Label sensor, Push-button switch
Text version of the page
QL50/QL55 SeriesSpecialty SensorsPHOTOELECTRICSSpecialty Sensors - 7106 QL55 Sensors62.3 mmPush-button programmingDetailedDimensionsBright LED indicators for operating and output status Robust metal housing 3-position swivel QD connector97.2 mm31.0 mm81.2 mm 31.0 mm81.2 mm 86.6 mm 79.6 mm QL55M6XD30BQ Model31.0 mmQL55M6XD15BQ ModelQL55M6XD50BQ ModelQL55, 10-30V dcDownload PDFModels Sensing Beam/LED*Sensing RangeCable/Connector**OutputTypeData SheetQL55M6XD15BQ 9-18 mm4-pin Euro QDOne selectable NPN or PNPdiscrete plus one0 to 5.5V dc analogQL55M6XD30BQ 20-40 mm 112153DIFFUSEQL55M6XD50BQ 40-75 mm* Black Ultraviolet LED Returned Luminescence ** Mating cable required (see page 380).QL55 SpecificationsSpot DiameterQL55M6XD15BQ: 2 mm QL55M6XD30BQ: 3 mm QL55M6XD50BQ : 4 mm Supply Voltage 10 to 30V dc, 2 V pp max ripple80 mA max @ 30V dc (excluding output current) Supply Protection Circuitry Protected against reverse polarity Output Configuration Discrete NPN or PNPAnalog 0 to 7V dc ± 10%, ripple 40 mV pp max. Saturation voltage: 1V max. NPN / 2V max PNP Leakage current: less than 100 µA Output Rating 200 mA max. load Output ProtectionNPN/PNP: Protected against reverse polarity, overload and short circuit(pull down/up resistance 10 k ) Analog: Protected against short circuit (output resistance 2.2 k ) Output Response Time 250 microsecondsMore information online atbannerengineering.com 213 |
|