Safety Modules - BANNER ENGINEERING - #29

/ 30


catalogue search
P. 01
P. 02
P. 03
P. 04
P. 05
P. 06
P. 07
P. 08
P. 09
P. 10
P. 11
P. 12
P. 13
P. 14
P. 15
P. 16
P. 17
P. 18
P. 19
P. 20
P. 21
P. 22
P. 23
P. 24
P. 25
P. 26
P. 27
P. 28
P. 29
P. 30
Pages:


See other catalogues for BANNER ENGINEERING

Text version of the page
SAFETY MODULES
interface Modules
Interface Modules
Model
Supply Voltage
Inputs
Safety Outputs
Output Rating
Aux. Outputs
Output Response Time
Data Sheet
IM-T-9A
3 NO
24V dc
2 NC (dual)
6 amps
20 ms
62822
IM-T-11A
2 NO
1 NC
NC = Normally Closed Relay, NO = Normally Open Relay
Interface Modules Specifications
Input Voltage and Current
24V dc, +/-15% no polarity, 10% max. ripple; 50 mA per input channel Power consumption: approx. 2.4 W
A
TI
m
-<
1 O
a c
r­m
Supply Protection Circuitry
Protected against transient voltages.
Output Configuration
IM-T-9A: 3 normally open output channels
IM-T-11A: 2 normally open output channels and 1 normally closed auxiliary output channel. Each normally open output channel is a series connection of contacts from two forced-guided (positive-guided) relays, K1-K2.
The normally closed contact 31-32 is a parallel connection of contacts from K1-K2. Contacts: AgNi, 5 urn gold-plated
Low Current Rating:
Caution: The 5 urn gold-plated contacts allow the switching of low current/low voltage.
To preserve the gold plating on the contacts, the following max. values should not be exceeded at any time: Min. voltage: 1V ac/dc Max. voltage: 60V
Min. current: 5 mA ac/dc Max. current: 300 mA
Min. power: 5 mW (5 mVA) Max. power: 7 W (7 VA)
High Current Rating:
If higher loads must be switched through one or more of the contacts, the minimum and maximum values of
the contact(s) changes to:
Min. voltage: 15V ac/dc Max. voltage: 250V ac/dc
Min. current: 30 mA ac/dc Max. current: 6 A
Min. power: 5 W (5 VA) Max. power: 200 W (1,500 VA)
Mechanical life: 50,000,000 operations
Electrical life: 150,000 operations (typical, @ 200 W (1,500 VA) switched power, resistive load)
PICO-GUARD CONTROLLERS
E-STOP/GUARD MONITORING
SAFETY MAT MONITORING
MUTING MODULES
EXTENSION
MODULES
NTERFACE MODULES
Feedback contact rating (Y1-Y2, Y3-Y4): Min. voltage: 1V ac/dc Min. current: 5 mA ac/dc Min. power: 5 mW (5 mVA)
Max. voltage: 60V Max. current: 300 mA Max. power: 7 W (7 VA)
Note: Transient suppression is recommended when switching inductive loads. Install suppressors across load. Never install suppressors across output contacts.
Output Response Time
20 milliseconds max.
Status Indicators
2 green LED indicators:
K1 energized K2 energized
Construction
Polycarbonate housing.
Environmental Rating
Rated NEMA 1; IEC IP20.
Mounting
Mounts to standard 35 mm DIN rail track. Interface Module must be installed inside an enclosure rated NEMA 3 (IEC IP54), or better.
Vibration Resistance
10 to 55Hz @ 0.35 mm displacement per IEC 68-2-6
Operating Conditions
Temperature: 0° to +50° C
Relative humidity: 90% @ 50° C (non-condensing)
More information online at bannerengineeringx^m 133

pageCatalog pdf di En 2012-05-22-28