You may also be interested in
Diffuse reflection sensor, LED indicator, Laser sensor, Color sensor, Scanner
Text version of the page
SAFETY INTERLOCK SWITCHESCompact Plastic Style Safety SwitchesSafety Interlock Switches - 7106 SI-QS75 and SI-QS90 Flat-Pack Style Switches SpecificationsContact Rating European Rating 10A @ 24V ac, 10A @ 110V ac, 6A @ 230V ac6A @ 24V dc 2.5 kV max. transient tolerance NEMA A300 P300 Utilization categories: AC15 and DC13 (IEC 60947-5-1)Switches with 1 & 2 contact pairs: U40-60 HzU e V I e /AC-15AI e /DC-13A241061101012306.4 i = 500V ac, I th = 10ASwitches with 3 contact pairs: U i = 400V ac, I th = 5A Contact Material Silver-nickel alloy Maximum Switching Speed 30 operations per minute Maximum Actuator Speed 1 m/second Mechanical Life 1 million operations Minimum Actuator Engagement RadiusIn-line actuators: 150 mm Flexible actuators: 50 mm in all directions Actuation Extraction Force 10 N; High force models: 50 N Short Circuit Protection 6 amp Slow Blow, 10 amp Fast Blow. Recommended external fusing or overload protection. Wire Connections Screw terminals with pressure plates accept the following wire sizes – 20 AWG (0.5 mm For switches with one or two contacts: Stranded and solid: 2 ) to 16 AWG (1.5 mm 2 ) for one wire Stranded: 20 AWG (0.5 mm 2 ) to 18 AWG (1.0 mm 2 ) for two wires SAFETY INTERLOCK SWITCHES For switches with three contacts:Stranded and solid: 20 AWG (0.5 mm 2 ) to 18 AWG (1.0 mm 2 ) for one w ire Stranded: 20 AWG (0.5 mm 2 ) to 18 AWG (1.0 mm 2 ) for two wires Cable Entry M20 x 1.5 for SI-QS90 and M16 x 1.5 for SI-QS75 threaded entrance. Adapter supplied to convert M20 x 1.5 to ½" - 14 NPT threaded entrance. Construction Glass fiber-reinforced thermoplastic UL94-VO rating Environmental Rating IEC IP65Note: Addition of a No. 3 x ¼" screw (max) to the wiring access door increases sealing to IEC IP67; NEMA 4X PICO-GUARDSWITCHES Operating Temperature -30° to +80° C MAGNET STYLE SWITCHESHINGE STYLESWITCHES WeightSI-QS75 models: 0.11 kg SI-QS90 models: 0.13 kg Application Notes Certifications Models with one and two contacts have three cable entry locations (bottom and two sides); models with three contacts have two cable entry locations (two sides). All entry locations are sealed with knockouts. To remove knockouts, thread the supplied M16 x 1.5 or M20 x 1.5 to ½" - 14 NPT conduit adapter or optional M16 x 1.5 or M20 x 1.5 cable gland into one of the threaded entry locations. The knockout will break open just before the adapter or cable gland bottoms out. For a list of certifications see page 238. Contact Configuration and Switching DiagramsSI-QS75 models: SD013 (p. 242) PLASTIC STYLE SWITCHES SI-QS90 models: SD014, SD015 and SD016 (p. 242) METAL STYLE SWITCHESLOCKING STYLESWITCHES More information online atbannerengineering.com 153 |
|