You may also be interested in
Safety light curtain, Indicator, Safety controller, Tower light, Indicator light
Text version of the page
LT7 SeriesL-GAGE®SensorsLight Gauging Sensors - 7106 LT7 Specifications (cont’d) LT7 SpecificationsEnvironmental Rating IEC IP67 Connections 12-pin M16 connector; 100 m max. cable length; use only cables listed on page 385 Operating ConditionsTemperature: -10° to +50° C in continuous operation Storage Temperature -30° to +75° C Vibration/Shock EN 60947-5-2 Application Notes • All specifications are based on the specified surface at constant ambient conditions and following a minimum operating time of 15 minutes.• For best accuracy, allow a 15-minute warmup before programming or operating • Crosstalk avoidance: Light spots must be separated by at least 200 mm. Certifications Hookup Diagrams MI31 (p. 499)Class 1 (Infrared Sensing Laser) Class 2 (Visible Alignment Laser)Lasers that are safe under reasonably foreseeable conditions of operation, including the use of optical instruments for intrabeam viewing. Reference 60825-1 Amend. 2 © IEC:2001(E), section 8.2. Lasers that emit visible radiation in the wavelength range from 400 to 700 nm where eye protection is normally afforded by aversion responses, including the blink reflex. This reaction may be expected to provide adequate protection under reasonably foreseeable conditions of operation, including the use of optical instruments for intrabeam viewing. Reference 60825-1 Amend. 2 © IEC:2001(E), section 8.2.Operating ModeOperatingModeLaser Class 1LaserClass1Setup ModeSetupModeLaser Class 2LaserClass2 MEASUREMENT & INSPECTION Do not stare into beamDonotstareintobeamMore information online atbannerengineering.com 275 |
|