FI22 Expert™ Series
Fiber Systems
FI22 Expert™, 10-30V dc
X
o o
m r­m O H
Sensing Mode/LED*
Output Type
Excess Gain
Beam Pattern
Data
Sheet
Cable**
Models
Range
Opposed mode: EGCP-42, EGCP-43 &
EGCP-44
(p. 449)
Diffuse mode: EGCP-45,
EGCP-46 &
EGCP-47
(p. 449)
Opposed mode:
BPP-36, BPP-37 & BPP-38
(p. 467)
Diffuse mode: BPP-39,
BPP-40 & BPP-41
(p. 467)
FI22FP
2 m
Range varies by sensing mode and fiber optics used. See data
sheet part number 108899 for maximum
range specifications.
D-H
□=!=>
PLASTIC FIBER
Bipolar
NPN/PNP
108899
FI22FPQ
6-pin Pico QD
—► Visible Red LED
For 9 m cable, add suffix W/30 to the 2 m model number (example, FI22FP W/30). A model with a QD requires a mating cable (see page 379).
FI22 Expert™ Specifications
Supply Voltage
10 to 30V dc (10% max. ripple) @ less than 32 mA exclusive of load
Supply Protection Circuitry
Protected against reverse polarity, over voltage, and transient voltages
Delay at Power Up
250 milliseconds max.; outputs do not conduct during this time
Output Configuration
Bipolar: 1 current sourcing (PNP) and 1 current sinking (NPN)
Output Rating
100 mA max. load @25° C (derate 1 mA per ° C increase) OFF-state leakage current: less than 50 at 30V dc
ON-state saturation voltage: NPN: less than 200 mV @ 10 mA and 1V @ 100 mA load PNP: less than 1.5V @ 10 mA and 2.0V @ 100 mA load
Output Protection
Protected against output short-circuit, continuous overload, transient over-voltages, and false pulse on power up
Output Response Time
500 microseconds
Repeatability
100 microseconds
Adjustments
2 push buttons and remote wire
• Expert TEACH programming (two-point static, dynamic and single-point static)
• Manually adjust (+/-) thresholds (from buttons only - not available from remote wire)
• LO/DO and OFF Delay configurable (from buttons or remote wire)
• Push-button lockout (from remote wire only)
Indicators
8-segment red bargraph: Light-to-dark signal difference relative to taught condition (single-point TEACH) Sensing contrast (two-point TEACH) Green LED: Power ON Yellow LED: Output conducting
Construction
PC/ABS blend plastic housing; polycarbonate cover
Environmental Rating
IP67; NEMA 6
Connections
5-conductor 2 m PVC cable, 9 m PVC cable, or 6-pin integral Pico-style quick-disconnect fitting. QD cables are ordered separately. See page 379.
Operating Conditions
Temperature: -10° to +55° C Relative humidity: 90% @ 50° C (non-condensing)
Certifications
C € c^lus