| | | FI22 Expert™ Series Fiber Systems | | |
| | | |
| | | FI22 Expert™, 10-30V dc | | |
| | | X o o m rm O H | | |
| | | |
| | | Sensing Mode/LED* | | Output Type | | |
| | | Excess Gain | | Beam Pattern | | Data Sheet | | |
| | | Cable** | | |
| | | Models | | | Range | | |
| | | | | |
| | | |
| | | |
| | | |
| | | |
| | | Opposed mode: EGCP-42, EGCP-43 & EGCP-44 (p. 449) Diffuse mode: EGCP-45, EGCP-46 & EGCP-47 (p. 449) | | Opposed mode: BPP-36, BPP-37 & BPP-38 (p. 467) Diffuse mode: BPP-39, BPP-40 & BPP-41 (p. 467) | | |
| | | FI22FP | | 2 m | | |
| | | Range varies by sensing mode and fiber optics used. See data sheet part number 108899 for maximum range specifications. | | |
| | | | |
| | | D-H □=!=> PLASTIC FIBER | | |
| | | Bipolar NPN/PNP | | |
| | | 108899 | | |
| | | |
| | | |
| | | |
| | | FI22FPQ | | | 6-pin Pico QD | | |
| | | |
| | | |
| | | |
| | | |
| | | —► Visible Red LED For 9 m cable, add suffix W/30 to the 2 m model number (example, FI22FP W/30). A model with a QD requires a mating cable (see page 379). | | |
| | | |
| | | | | | | | | | FI22 Expert™ Specifications | | | | Supply Voltage | 10 to 30V dc (10% max. ripple) @ less than 32 mA exclusive of load | | | | Supply Protection Circuitry | Protected against reverse polarity, over voltage, and transient voltages | | | | Delay at Power Up | 250 milliseconds max.; outputs do not conduct during this time | | | | Output Configuration | Bipolar: 1 current sourcing (PNP) and 1 current sinking (NPN) | | | | Output Rating | 100 mA max. load @25° C (derate 1 mA per ° C increase) OFF-state leakage current: less than 50 at 30V dc ON-state saturation voltage: NPN: less than 200 mV @ 10 mA and 1V @ 100 mA load PNP: less than 1.5V @ 10 mA and 2.0V @ 100 mA load | | | | Output Protection | Protected against output short-circuit, continuous overload, transient over-voltages, and false pulse on power up | | | | Output Response Time | 500 microseconds | | | | Repeatability | 100 microseconds | | | | Adjustments | 2 push buttons and remote wire • Expert TEACH programming (two-point static, dynamic and single-point static) • Manually adjust (+/-) thresholds (from buttons only - not available from remote wire) • LO/DO and OFF Delay configurable (from buttons or remote wire) • Push-button lockout (from remote wire only) | | | | Indicators | 8-segment red bargraph: Light-to-dark signal difference relative to taught condition (single-point TEACH) Sensing contrast (two-point TEACH) Green LED: Power ON Yellow LED: Output conducting | | | | Construction | PC/ABS blend plastic housing; polycarbonate cover | | | | Environmental Rating | IP67; NEMA 6 | | | | Connections | 5-conductor 2 m PVC cable, 9 m PVC cable, or 6-pin integral Pico-style quick-disconnect fitting. QD cables are ordered separately. See page 379. | | | | Operating Conditions | Temperature: -10° to +55° C Relative humidity: 90% @ 50° C (non-condensing) | | | | Certifications | C € c^lus | | | | Hookup Diagrams | DC11 (p. 478) | | | | | | | | | |
| | | |