For your nearest distributor, call 800-462-9832 or www.bkprecision.com 57
A great tool for professionals in the cable TV industry as well as in
the telecommunication. It is a value packed service tool for signals
up to 1.05GHz. All three models are suitable for pre-compliance
testing during development prior to third party testing.
An optional near-field sniffer probe set (PR-261) can be used to
locate cable and PC board emission hot spots and evaluate EMC
problems at the breadboard and prototype level. The spectrum analyzer/
sniffer probe combination is an excellent solution for RF leakage/
radiation investigation, CATV/MATV system troubleshooting,
cellular telephone/pocket pager test and EMI diagnostics.
Convenient carrying case is available.
Models 2625, 2630 & 2635
Performance
” 150kHz to 1.05GHz (1050MHz)
” Dynamic Range 80dB (113dB with attenuation)
” AM & FM demodulator included
” 20 and 400 kHz resolution bandwidth
” 150kHz/hour stability
” Built-in tracking generator (Model 2630 & 2635)
Applications
” Test cable TV levels and frequency response
” Test master antenna TV systems
” Measure communications transmitter spurious
radiation
” Locate sources of EMI
” Measure unwanted RF radiation
Model 2635
” Save/Recall
” Frequency and level marker
” RS-232 interface
Frequency 1.05GHz (1050MHz)
Frequency range 0.15MHz to 1.05GHz (1050MHz) (-3dB)
Center frequency display accuracy ±100kHz
Marker accuracy ±(0.1% span + 100kHz)
Frequency display resolution 100kHz (4 digit LED)
Frequency scanwidth 100kHz/div to 100MHz/div in 1-2-5 steps and 0Hz/div (Zero Scan)
Frequency scanwidth accuracy ±10%
Frequency stability Drift: <150kHz/hour
IF Bandwidth (-3dB) Resolution: 800kHz and 20kHz. Video-Filter on: 4kHz
Sweep rate 43Hz
AMPLITUDE
Amplitude range -100dBm to +13dBm
Screen display range 80dB (10dB/div.)
Reference level -27dBm to +13dBm (in 10dB steps)
Reference level accuracy ±2dB
Average noise level -99dBm (12.5kHz BW)
Second and third harmonic <-75dBc
Third order intermod. -70dBc (two signals >3MHz apart)
Log scale fidelity ±2dB (without attn.) 250MHz
IF gain 10dB adjustment range
INPUT
Input impedance 50Ł
Input connector BNC
Input attenuator 0 to 40 dB (4 x 10dB steps)
Input attenuator accuracy ±1dB
Maximum input level +10dBm, ±25VDC (with 0dB attenuation);
+20dBm (with 40dB attenuation)
TRACKING GENERATOR (Model 2630 & 2635)
Output level range -50dBm to +1dBm (in 10dB steps and var.)
Output attenuator 0 to 40dB (4 x 10dB steps)
Output attenuator accuracy ±1dB
Output impedance 50Ł (BNC)
Frequency range 0.15MHz to 1050MHz
Frequency response ±1.5dB
Radio Frequency Interference (RFI) <20dBc
GENERAL
Operating temperature 50° to 122°F (10°C to 50°C)
Display CRT. 6 inch, 8 x 10 div. internal graticule
Trace rotation Adjustable on front panel
Line voltage 90-260Vac, 50/60 Hz (125V, 400Hz)
Power consumption approx. 20W
Max. ambient temperature 14° to 104°F (-10°C to+40°C)
Protective system Safety Class I (IEC 348)
Weight approx. 13.2 lbs. (6.0 kg)
Dimensions (HxWxD) 4.9 x 11.2 x 15" (125 x 285 x 380mm)
2625
2635
2630
SUPPLIED: Instruction Manual, Power Cord, Software(2635 only)
O
S
R
Specifications models
2625, 2630 & 2635
Accessories One Year Warranty
|
|