Power Meter Model 5335B - 6 Pages

  1. P. 1

  2. P. 2

  3. P. 3

  4. P. 4

  5. P. 5

  6. P. 6

Catalogue excerpts

Data Sheet The 5335B is a compact, single-phase AC / DC power meter for measuring and analyzing power consumption and power quality parameters quickly and accurately. It supports power measurements up to 600 Vrms and 20 Arms, with a bandwidth up to of 100 kHz. Applications Measure power, electrical energy bought or sold back to the power grid, inverters, harmonics of motors, un-interruptible power supplies, appliances, and consumer electronics. Features & Benefits ■ 600 Vrms ( Cat II ) and 20 Arms direct input ranges ■ Frequency ranges DC, 0.5 Hz to 100 kHz ■ 0.1% basic accuracy for voltage and current measurements Rich Measurement Functions Measure all AC and DC parameters, including power, current, voltage, power factor, frequency, and phase. Additionally, the meter features a powerful integration function, the ability to perform harmonic measurements to the 50th order and an oscilloscope mode for viewing voltage and current readings in the time domain. 12 real-time parameters can be measured and displayed simultaneously in user customizable views. ■ 4.3-inch color LCD (TFT) ■ Simultaneously measure and display up to 12 measurement parameters ■ Capture inrush current, and voltage surge with the peak function ■ Harmonic measurements to the 50th order ■ Integration function with automatic range switching ■ Ability to measure electrical energy which is produced or consumed ■ Pre-compliance testing according to IEC/EN 62000-3-2 / 4-7 ■ Standard USB (USBTMC-Compliant), GPIB, RS232 and LAN interfaces ■ Line and frequency filter capability for reducing unwanted signal noise ■ Optional universal breakout box to simplify connection between power meter and DUT Technical data subject to change © B&K Precision Corp. 2017

 Open the catalogue to page 1

Front panel USB host port Main measurement function keys Power button Rotary control knob Navigation keys Menu keys Intuitive user interface The large 4.3 inch color LCD screen enables easy viewing of configuration and measurements. Use the dedicated function keys to select one of the 4 main measurement modes: meter, harmonic, integral or oscilloscope. The results are displayed in numeric and graphical format. Screenshots can be saved directly to a USB flash drive. Rear panel GPIB interface Current input terminals Voltage input terminals External sensor interface Trigger input

 Open the catalogue to page 2

Harmonic measurement Voltage, current, active power, reactive power and phase values of each harmonic can be measured and displayed as a list or bar chart, enabling the user to quickly visualize and analyze the results. Total harmonic distortion (THD) can be evaluated up to the 50th order with the ability to display individual harmonic components. Integration measurement The integration function is useful for analyzing bought and sold electrical energy of a grid tied power systems. The 5335B meter provides current integral and active power integral (Wh) functionality using automatic range switching...

 Open the catalogue to page 3

Specifications Specifications are subject to the following conditions Temperature: 23±5° C, humidity: 30 to 75% RH. Warm-up time: 30 minutes General Measurement Specifications 1 Input signal frequency in kHz 2 Input waveform: Sine wave crest factor: 3, common-mode voltage: 0 V, power factor: 1 Frequency filter: Turn on when measuring < 200 Hz

 Open the catalogue to page 4

Current Measurement Accuracy and Ranges Direct input range Sensor input range Accuracy 2 (line, frequency, & digital filter set to off) 5 pA/ °C (after zero-level compensation, or range change) Temperature coefficient 500 pA/ °C (after zero-level compensation, or range change) Influence of internal sensor self-heating + 0.00013 x I2 % of reading to the AC current accuracies + 0.00013 x I2 % of reading + 0.004 x I2 mA (0.5 to 20 A) or 2 2 0.00013 x I2 % of reading + 0.00004 x I2 mA (2.5 to 200 mA), add to the DC current accuracy specifications Power Measurement Accuracy Frequency Measurement Accuracy Frequency...

 Open the catalogue to page 5

All B&K Precision catalogues and technical brochures

  1. Model 627

    1 Pages

    En
  2. Model 625

    1 Pages

    En
  3. Model 635

    1 Pages

    En
  4. Model 710

    1 Pages

    En
  5. Model 636

    1 Pages

    En
  6. Model 615

    1 Pages

    En
  7. Model 630

    1 Pages

    En
  8. Model 1211E

    1 Pages

    En
  9. Model 231A

    2 Pages

    En
  10. Model 262

    1 Pages

    En
  11. LCR Meter

    1 Pages

    En
  12. 9110 & 9111

    1 Pages

    En
  13. 1651A & 1652

    1 Pages

    En
  14. Model 1692

    1 Pages

    En
  15. Models 167x A

    1 Pages

    En
  16. 9200 Series

    4 Pages

    En
  17. XLN series

    5 Pages

    En
  18. 9800 series

    5 Pages

    En
  19. Component Tester

    1 Pages

    En
  20. Light Meter

    1 Pages

    En

Archived catalogues