You may also be interested in
Multimeter, Programmer, Generator, Sound level meter, Capacitance meter
Text version of the page
Bench LCR/ESR Meter with Component Test
Model 889B
Data sheet
Technical data subject to change
© B&K Precision Corp. 2008
v091009
www.bk precision.com
Tel.: 714.921.9095
Frequency 100Hz, 120 Hz, 1 kHz, 10 kHz, 100 KHz, 200 kHz
Frequency Accuracy ±0.1%
Level 1 Vrms, 0.25 Vrms, 0.05 Vrms, 1 Vdc (for DCR)
level Accuracy ±5%
Output Impedance 100 Ù, ±5%
Measurement Range
Impedance (Z)
Frequency Maximum Minimum Best Resolution
DCR 20 MÙ 0.1 Ù 0.001
100 Hz 20 MÙ 0.1 Ù 0.001
120 Hz 20 MÙ 0.1 Ù 0.001
1 kHz 20 MÙ 0.1 Ù 0.001
10 kHz 20 MÙ 0.1 Ù 0.001
100 kHz 20 MÙ 0.1 Ù 0.001
200 kHz 20 MÙ 0.1 Ù 0.001
Capacitance (C)
Frequency Maximum Minimum Best Resolution
100 Hz 15.91 mƒ 79.57 pƒ 0.001
120 Hz 13.26 mƒ 66.31 pƒ 0.001
1 kHz 1.591 ìƒ 7.957 pƒ 0.001
10 kHz 159.1 ìƒ 0.795 pƒ 0.001
100 kHz 15.91 pƒ 0.159 pƒ 0.001
200 kHz 0.079 pƒ 795.7 pƒ 0.001
Inductance (L)
Frequency Maximum Minimum Best Resolution
100 Hz 9999 H 159.1 ìH 0.001
120 Hz 9999 H 132.6 ìH 0.001
1 kHz 3183 H 15.91 ìH 0.001
10 kHz 318.3 H 1.591 ìH 0.001
100 kHz 31.83 H 0.159 ìH 0.001
200 kHz 15.91 H 0.159 ìH 0.001
GENERAL
Operating Temperature 32° to 104°F (0° to 40°C)
Storage Temperature -4° to 158°F (-20° to 70°C)
Relative Humidity up to 85%
AC Operation 110V/220V AC, 60/50Hz
Low Power Warning under 2.2V
Dimensions (LxWxH) 11.8 x 8.7 x 5.9" (300 x 220 x 150mm)
Weight 10 lbs (4.5 kg)
Accessories
Supplied: Instruction Manual, Kelvin Probe, line Cord
Specifications
889B
One Year Warranty
model
The B&K Precision Corp. 889B Synthesized In-Circuit LCR/ESR Meter is a
high accuracy test instrument used for measuring inductors, capacitors and
resistors with a basic accuracy of 0.1%. Also, with the built-in functions of
DC/AC Voltage/Current measurements and Diode/Audible Continuity checks,
the 889B can not only help engineers and students to understand the
characteristics of electronics components but also being an essential tool on
any service bench.
Features:
Measurement parameters: Z, L, C, DCR, ESR, D, Q, ACV,
DCV, ACA, DCA and Ø
Test conditions: 100 Hz, 120 Hz, 1 kHz, 10 kHz, 100 KHz,
200 kHz, 1 Vrms, 0.25 Vrms, 0.05 Vrms
0.1% basic accuracy
Dual LCD display
Very quick response, user friendly
Fully auto/manual selection
DC resistance measurement
USB interface
|
|