You may also be interested in
Audio signal generator, Clamp multimeter, Tester, Digital oscilloscope, Linear power supply
Text version of the page
CR Mode Regulation 0.1 -10 Ù ±(1%+0.3% FS) 0.001 Ù
(Input current FS 10% 10-99 Ù ±(1%+0.3% FS) 0.01 Ù
Input Voltage FS 10%) 100-999 Ù ±(1%+0.3% FS) 0. 1 Ù
1K-4 KÙ ±(1%+0.8% FS) 1 Ù
CW Mode Regulation 0-100 W ±(1%+0.1% FS) 1 mW
(Input current FS 10% 100 W – max Power ±(1%+0.1% FS) 100 mW
Input Voltage FS 10%)
Power Measurement 0-100 W ±(1%+0.1% FS) 1 mW
(Input current FS 10% 100-max Power ±(1%+0.1% FS) 100 mW
Input Voltage FS 10%)
Battery testing function Input = 0.1 V – 120 V Max measurement capacity = 999 A*hr
Resolution = 10 mA Timer range = 1-60000 sec
Transition Mode Range of Frequency 0.1 Hz-1 kHz Frequency error rate.. 0.5%
8500 215 mm×88 mm×355 mm (8.46 in x 3.46 in x 14 in) 5.2 kg (11.5 lbs)
8502 215 mm×88 mm×355 mm (8.46 in x 3.46 in x 14 in) 5.2 kg (11.5 lbs)
8510 429 mm×88 mm×355 mm (16.9 in x 3.46 in x 14 in) 14 kg (31 lbs)
8512 429 mm×88 mm×355 mm (16.9 in x 3.46 in x 14 in) 14 kg (31 lbs)
8514 429 mm×88 mm×355 mm (16.9 in x 3.46 in x 14 in) 14 kg (31 lbs)
8518 429 mm×88 mm×355 mm (16.9 in x 3.46 in x 14 in) 14 kg (31 lbs)
8520 444 mm×180 mm×539 mm (17.48 in x 7.09 in x 21.22 in) 30 kg (66 lbs)
8522 444 mm×180 mm×539 mm (17.48 in x 7.09 in x 21.22 in) 30 kg (66 lbs)
8524 444 mm×357 mm×539 mm (17.48 in x 14.06 in x 21.22 in) 67 kg (148 lbs)
8526 444 mm×357 mm×539 mm (17.48 in x 14.06 in x 21.22 in) 67 kg (148 lbs)
Accessories
Supplied: Power cord, user manual, installation CD
with application software, TTL to RS232
serial converter IT-131
Optional: Rack mount kit IT-E151, TTL to USB
serial adapter IT-132
6 www.bk prec ision.com
DC Electronic Loads
Models 8500, 8502, 8510, 8512, 8514, 8518, 8520, 8522, 8524, 8526
Common characterist ics
Mechanical specifi cations
All 8500 DC load models
Parameter Range Accuracy Resolution
Model number Dimensions (W x H x D) Weight One Year Warranty
|
|