You may also be interested in
Temperature controller, Detector, Photoelectric sensor, Pressure transmitter, Thermal mass flow-meter
Text version of the page
SPECIFICATIONSFL7M-3T7HD(-CN,-CN03) FL7M-7T7HD(-CN,-CN03) FL7M-10T7D(-CN,-CN03) (-CN,-CN03) 10 ± 1mm 0 to 2.4mm 0 to 5.6mm 0 to 8mm 10% max. of sensing distance 40 to 250Vac, 20 to 250Vdc -25 to +70ËšC-10 to +60ËšC When AC power supply is used 25HzWhen AC power supply is used 1KHz When AC power supply is used 25Hz When AC power supply is used 500Hz When AC power supply is used 25Hz When AC power supply is used 400Hz ± 10% max. for the range of -25 to +70ËšC when +25ËšC is taken as standard temperature in sensing distance. -10 to +60ËšC 4,000Vac, 50/60Hz for 1minute 980 m/s2 10 time in X,Y and Z directions Approx. 90gMain unit with 2m pre-leaded cableApprox. 160gMain unit with 2m pre-leaded cable Approx. 270gMain unit with 2m pre-leaded cable Ni-plated brass PBT -CN :Ni-plated Zn, -CN03 :polyester elastomer -CN :Sn-plated brass, -CN03 :Gold-plated brass ABOUT SETTING INDICATION WIRING DIAGRAMProximity Sensors - 18885 2 |
|