Weld Shield Gas Flow Switch - AW-Lake Company - #2

/ 2


catalogue search
P. 01
P. 02
Pages:


See other catalogues for AW-Lake Company

Text version of the page

WWeld Shield Gas Feld Shield Gas Flolow Switcw Switchh

MATERIALS OF CONSTRUCTION

WETTED COMPONENTSNON-WETTED COMPONENTS ComponentMaterialsComponentMaterials CasingBrass CA360Switch ElementABS / Epoxy SealBuna-N (STD)CablePVC Transfer MagnetBonded PPS / FerriteCord GripNylon Floating OrificeBrass CA360Retainer ScrewStainless SteelAll other internal partsStainless SteelScaleBrass/Epoxy

PERFORMANCE

Flow measuring accuracy:±5% of range Repeatability: ±2% of range Flow measuring range:See Lake’s guide to standard flow meters for specific ranges Maximum operating pressure:150 PSIG (10.3 Bar) Maximum operating temperature:240°F (116°C) Standard calibration fluids:Nitrogen, CO
2 , Argon C25 @ 70°F (43°C), 30 PSIG Filtration requirements:74 micron filter or 200 mesh screen minimum Response Time:

B A CD

DIMENSIONS

DIM1/4" NPTF3/8" NPTF A4.28" (109mm)4.43" (113mm) B1.48" (38mm)1.48" (38mm) C1.42" (36mm)1.42" (36mm) D0.88" (23mm)0.88" (23mm)
LAKE MONITORS, 2013 South 37th Street, Milwaukee, WI 53215414.671.3577 / 800.850.6110 / Fax: 414.671.5253 WGDS-1205 1M CJK/MAS © Lake Monitors Inc. 2005

www.lakemonitors.com


pageCatalog pdf di En 2012-05-22-28