Lake MonitorsVisi Rate Lake Monitors Visi Rate
Economical way to monitor municipal-pressure water flows,
observe case industrial drain flows and verify
industrial pump outputs.
FOR 1/4" – 1" PIPE SIZES
UNRESTRICTED MOUNTING PATENTED SENSING METHOD ASSURES ACCURACY Allows the designer to install the monitor in anyorientation — horizontal, vertical or inverted.
Two scale positions available for scale reading ease. The Helical-Torque sensing method assures accuracy of ±5% of range, even with variable
fluid parameters. COMPACT AND RUGGED DESIGN Measures less than 5-1/2" long and 2" diameterwith a tough polysulphone body of construction. SUPERIOR READABILITY Extra long 3-1/2" scale, provides excellent flowrate measuring resolution along with dual units
of GPM and LPM. VISUAL INSPECTION OF FLUID 14 PORT SIZES AVAILABLE The transparent body allows for visual inspectionof fluid conditions. Diagnose problems at a
glance. Standard selection of NPT, SAE and BSP portsreduces the amount of adapters required for
installation. LOW COST PRECISION Measuring accuracy of ±5% of range and repeatability of ±1%. >
ENGINEERING SPECIFICATION THE VISI-RATE METER SHALL: ? Use the mass axial turbine rotation to measure
flow rate. ? Not require inlet or outlet straight plumbing, or require vertical pipe mounting. ? Have a measuring accuracy of ±5% of full scale
with ±1% repeatability. ? Use the helical-torque sensing method to measure flow. ? Be Lake Monitors No. VRB - _ _ - _ _ for flow
measuring or for a manufacturer of flow indicator be a VRI - _ _ www.lakemonitors.com