Visi Rate Visi

TYPICAL PRESSURE DIFFERENTIALS MATERIALS OF CONSTRUCTION (WETTED COMPONENTS) BRASSSTAINLESS STEEL End Ports BrassStainless Steel SealsBuna-NViton
® Spring (VRB Series)Stainless SteelStainless SteelTurbine and CasingPolysulphonePolysulphone
Viton is a registered trademark of Dow DuPont Elastomers PERFORMANCE
01234501234 Measuring Accuracy:±5% of full-scale Repeatability:±1 % of full-scale Flow Measuring Range (VRB flow meters):1–30 GPM [5-110 LPM] Minimum flow detection (VRIflow meters):0.2 GPM [0.8 LPM] Maximum operating temperature:250°F [121°C] Maximum operating pressure:200 PSIG [14 bar] Pressure Differential:See graphs Filtration requirements:37 Micron (400 U.S. mesh) minimum MECHANICAL
024681001234 5678 DIM1/4" – 1/2" SIZES3/4" – 1" SIZES
048121601234567891011 A1-3/4" (45mm)1-3/4" 45mm) B3-1/2" (89mm)5-3/8" (137mm) Port SizesNPTF: 1/4", 3/8;" 1/2"NPTF: 3/4", 1" SAE: #6, #8, #10SAE: #12, #16BSPP: 3/8", 1/2"BSPP: 3/4", 1"
0612182430024 681012141618202224 LAKE MONITORS, 2013 South 37th Street, Milwaukee, WI 53215414.671.3577 / 800.850.6110 / Fax: 414.671.5253
VRDS-404 7.5M CK / WGD / MAS © Lake Monitors Inc. 2004

www.lakemonitors.com


pageCatalog pdf di En 2012-05-22-28