Flow Analyzers Data Sheet - AW-Lake Company - #2

/ 2


catalogue search
P. 01
P. 02
Pages:


See other catalogues for AW-Lake Company

Text version of the page

R100 and R/T100 Flow Analyzers R100 and R/T100 Flow Analyzers

MECHANICAL PERFORMANCE Enclosure size:1/8 DIN, 3.63” x 1.78” cutout Construction:high impact ABS Temperatures:Operating: +41ºF (5ºC) to +130ºF (54ºC) Storage:–40ºF (–40ºC) to +200ºF (93ºC) Humidity:0-90% non-condensing Weight:2 lbs. Connections:via terminal blocks ELECTRONIC PERFORMANCE Measuring accuracy:±0.25% maximum measuring error. Temperature stability:<20 ppm over operating range Input power:110VAC ±15% (8VA) or 12-24VDC (300mA) Display:6 digit red LED, 0, .55" high digits Analog inputs:4-20mA, 0-20mA, 0-5VDC, 1-5VDC or 0-10VDC Selectable from the front panelInput impedence:current inputs: 100 Ohms voltage inputs: 115K Ohms Resolution:14.5 bits Input protection:over voltage: 50V over current: 50mARelays:two SPDT, 10A @ 120//240VAC or 28VDC DIMENSIONS APPLICATION LAKE MONITORS, 2013 South 37th Street, Milwaukee, WI 53215414.671.3577 / 800.850.6110 / Fax: 414.671.5253
RTDS-404 7.5M CK / WGD / MAS © Lake Monitors Inc. 2004

www.lakemonitors.com


pageCatalog pdf di En 2012-05-22-28