Lake MonitorsBasic In-line LiquidFlow Rate Monitors Lake Monitors Basic In-line LiquidFlow Rate Monitors
Ideal for monitoring case drainflows, pump performance and media
flows through hydraulic circuits and
sub-circuits
FOR 1/8" – 2" PIPE SIZES STYLEB
CHOICE OF THREE MATERIALS OF CONSTRUCTION RUGGED AND RELIABLE Designed as a hydraulic service tool, this monitorwill provide years of maintenance-free performance. Select from aluminum, brass or stainless steel to meet system and media compatibility
requirements. UNRESTRICTED MOUNTING HIGH PRESSURE OPERATION Allows the designer to install the monitor in anyorientation – horizontal, vertical or inverted. The magnetically coupled follower and rigid
pressure vessel design allows operation to 6000PSIG and use with opaque liquids. SUPERIOR EXTERIOR DESIGN Weather-tight for use outdoors and/or on systems where wash downs are required. 24 DIFFERENT PORTS AVAILABLE Standard selection of NPT, SAE and BSP portsreduces the amount of adapters required for
installation. GOOD VISCOSITY STABILITY LOW COST ACCURACY A sharp-edged stainless steel orifice providesexcellent measurement stability for viscosities
from 0-500 SSU. ±2.5% of range accuracy in center third of scale;±4% in upper and lower thirds. BI-DIRECTIONAL AND REVERSE FLOWOPTION OFFERED Basic in-line monitors are also available in bi-directional and reverse flow versions. Contact Lake Monitors for more information. >
ENGINEERING SPECIFICATION THE IN-LINE FLOW RATE MONITOR SHALL: ? Use the variable annular orifice technique with
compression spring recoil. ? Not require inlet or outlet straight plumbing, or
require vertical pipe mounting. ? Have a measuring accuracy of ±2.5% of full scale
in the center third of the measuring range, and
±4% in upper and lower third. ? Have a stainless steel sharp-edged orifice. ? Have a weather-tight external construction. ? Be Lake Monitors No. B _ _ – _ _ _ – _ _ www.lakemonitors.com