FDDesign
GENERAL DESCRIPTION
FD series use metallized dielectric, controlled self-healingtechnology, high specific energy. >
USUAL APPLICATIONS
The FD
capacitors are designed for discharge applications
such as Laser, electronic flash, cardiac defibrillator, etc.FDseries offer a very high specific energy level, higher than1500J per liter for cardiac defibrillator application. >
ELECTRICAL CHARACTERISTICS
Operating temperature:–55°C to +85°C Storage temperature:–55°C to +85°CCapacitance range:5µF to 150µF other values on request Capacitance tolerance:±10%
Nominal charging voltage:1kV to 3kV >
DISCHARGE higher voltage on request Test voltage between terminals:@ 25°C: 1.2 x U >
N dc during 10sTest voltage between terminals and earth:@ 25°C: 2 U >
N dc during 1 min (type test) >
HOT SPOT CALCULATION
For all applications the temperature in the hot spot capacitor must be lower than 85°C θ >
hot spot = θ >
ambient + (tg δ >
x Q + R >
s I >
rms 2 ) x R >
th withtg δ >
= 2.10 >
-4 Q in Vars R >
s in Ohm I >
rms in Ampere R >
th in °C/W >
41