FFLC Design
DC FILTERING 1.61.41.21.0
0.8100100010000Lifetime Expectancy (hours)1000001000000 50 C70 dc n /V w V C85 C V >
w : permanent working or operating DC-voltage. >
ELECTRICAL CHARACTERISTICS
Climatic category40/85/56 (IEC 60068) FFLC overvoltage: (V >
s ): V >
s = 2 V >
n dc and limited at 2100VMaximum Peak valueMaximum duration overvoltage1.67V >
n dc100 ms1 time per week1.25V >
n dc100 ms1 time per day 1.1V >
n dc1 min1 time per dayTest voltage between terminals @ 25C 1.5 x V >
n dc for 10sTest voltage between terminals and case@ 25C @ 4 kVrms @ 50 Hz for 1 min. >
STANDARDS HOT SPOT CALCULATION
LIFETIME EXPECTANCY vsHOT SPOT TEMPERATURE AND VOLTAGE
IEC 61071-1: Power electronic capacitorsIEC61071-2: Power electronic
capacitors
IEC 60068-1: Environmental testingIEC 60077: Rules for electric traction equipmentUL 94: Fire requirementsNF F 16-101
NF F 16-102: Fire and smoke requirementsIEC 61881: Railway applications, rolling stockequipment, capacitors for powerelectronics θ >
hot spot = θ >
ambient + (P >
d + P >
t ) x R >
th withP >
d (Dielectric losses) = Q x tg δ >
⇒ [ >
1 ⁄ >
2 x C >
n x (V >
peak to >
peak ) >
2 x f ] x (2 x 10 >
-4 )P >
t (Thermal losses) = R >
s x (I >
rms ) >
2 whereC >
n in FaradI >
rms in Amperefin HertzVin VoltR >
s in Ohm θ in CR >
th in C/W >
24