You may also be interested in
Digital controller, Junction box, Platform scale, Vehicle scale, Scale
Text version of the page
Avery Weigh-Tronix Checkweighers
E1070
checkweigher
Technical Specification
DESCRIPTION
General
The E1070 Checkweigher from Avery Weigh-Tronix; combines rugged stainless steel construction with the proven accuracy of specially designed stainless steel load cells.
The Avery Weigh-Tronix E1070 checkweigher allows precise monitoring of the machinery that dispenses product and gives the option to fine-tune any operation for maximum performance and profitability.
The foundation of all Avery Weigh-Tronix checkweighers are Avery Weigh-Tronix bases, the industry standard for durability.
Design
The E1070 Checkweigher is completely wash-down safe and perfect for tough environments. It features stainless steel construction including base, column, load-cell and indicator enclosure. The standard indicator enclosure is adjustable from a vertical position to a tilt of 20 degrees.
Features
The E1070 includes a multi-segment fan graph for ¡¡fast evaluation. The operator can instantly verify that products are within the target range or above or below acceptable tolerance. In addition to its checkweighing feature also included are batching, counting, and peak measurement features.
The E1070 has the ability to grow and adapt to new ¡¡processes.
Switching easily from job to job, this indicator ¡¡applies to general weighing applications adding the capability of process control interface and data management.
Uncomplicated, the E1070 checkweigher provides ¡¡process control and data management. Offering the advantage of the built-in interfaces—Ethernet 10/100, PROFIBUS® and DeviceNet™—the indicator is ideally suited for sharing data.
In addition to network interfaces, the E1070 ¡¡connects to printers, remote displays, computers and SensorComm™. SensorComm is the Avery Weigh-Tronix micro-processor-based digital junction box.
The bright LED display with 20 mm (0.8 in) digits allows ¡¡the operator to view weights with a quick glance.
SPECIFICATIONS
Environment
14° to 104°F (-10° to +40°C) Water washdown
Humidity: 10% to 95% relative, non-condensing
Agencies
OIML, NTEP, EU Trade Approved, Canadian Weights and Measures, UL/CUL, CE marked, USDA compliant
Indicator
Power requirements
Standard: 85-265 VAC 50/60 Hz @ 0.3 Amp max.
Circuitry protection
RFI, EMI, and ESD protection
Display
Green LED 20 mm, displays up to six digits
Decimal Points: Configurable to any of six positions
Units Displayed: lb, kg, custom
Capacity selections: 999,999 with decimal located from zero to five places
Keypad
Numeric entry
One Function key
Dedicated Function Keys: Zero, Tare, Select, Print, Units, Standby, Escape, Enter, Clear
5Model E1070 Indicator Service ManualIntroductionAbout This ManualThis manual covers the information you need to configure and service yourModel E1070 Indicator.Major sections of this manual are headed by titles in a black bar like Intro-duction above. Subheadings appear in the left column. Instructions and textappear on the right side of the page. Occasionally notes, tips, and specialinstructions appear in the left column.Front PanelThe front panel, shown in Figure 1, consists of the keys and display.Figure 1E1070 front panel Plug the Model E1070 intoproperly grounded socket-outlet of the correct voltage,installed near the equipmentand easily accessible. Neveruse the unit without an appro-priate earthground connection.Any computer based systemshould have a separate,grounded power circuit. Werecommend one for theModel E1070.See the System Block Diagramor Main Board Assembly pagesin the technical illustrations atthe back of this manual forwiring instructions.
|
|