cad

Electric actuator IVM
13Pages

{{requestButtons}}

Catalog excerpts

Electric actuator IVM - 1

Tous les produits sont conformes RoHS

Open the catalog to page 1
Electric actuator IVM - 2

Linear Stepping Actuator Simple operation Simple setup Low cost Silent, clean Simple point-to-point operation. Simple stroke, acceleration/deceleration, thrust level settings. Open-loop control enables low cost. A linear motor and no deceleration mechanism greatly reduces operating noise. Grease-less for cleaner operation. Simple construction eliminates the need for maintenance.

Open the catalog to page 2
Electric actuator IVM - 3

User issues Use of electric robot too much AUTOMAX provides solutions to user problems with iV-Move, which delivers new value. Quiet, high-speed movement iV-Move application example Contents Features ························································ 1 Handling Instructions and Precautions ·········· 4 Actuator Specifications/Order Codes ············ 6 Dimensions ··············································· 7 Controller Specifications/Dimensions ············ 9 Wiring method ··········································· 11 Teaching box Specifications/Dimensions...

Open the catalog to page 3
Electric actuator IVM - 4

Handling Instructions and Precautions Selection System configuration diagram (example) Note 1: These graphs show thrust and levels at an ambient temperature of 25 °C [77 °F]. 2: Thrust changes within the graph range in accordance with the pressing point. IVM5 Normal TYPE I/O cable 2 m (Comes with controller) USB-RS485 converter (option) IVM-H1 USB cable Power cable 2 m (Comes with controller) General-purpose computer support software Note Note: A USB-RS485 converter is required to use the computer support software that comes with the product. iV Actuator operation mode Operation mode D mode...

Open the catalog to page 4
Electric actuator IVM - 5

Mounting • Installing the Main Unit (1) To prevent main unit heat buildup, be sure to mount it onto an item with the best possible heat conductivity in a location that has good heat dissipation properties. (2) Choose a flat surface as the mounting surface. Twisting or bending during mounting creates the risk of defective operation and loss of performance. (3) Note that a mounting surface that is scratched or dented can adversely affect mounting accuracy. (4) In cases where loosening of screws due to impact and/or vibration may be a factor, consider looseness prevention measures, etc. (5)...

Open the catalog to page 5
Electric actuator IVM - 6

Specifications Model 2-phase stepping, moving magnet system Maximum thrust Maximum speed Vertical useNote Position sensing Mounting methods Side mount A, B, and front mount Main unit: Aluminum alloy Mass (excluding cable) Operating temperature/humidity range Storage temperature Note: Values shown for thrust during vertical use are the thrust during horizontal use minus the mass of the moving part as it rises. The actual payload varies in accordance with customer use conditions. In particular, confirmation of the acceleration and deceleration and operating frequency in the case of vertical...

Open the catalog to page 6
Electric actuator IVM - 7

Stroke Origin Stroke end Machine stop end (extended side) Machine stop end (retracted side) Cable holder (with screws) Shipped with product V-groove (For reference plane identification) Machine screw for ground Shipped with product Stroke Stroke end Machine stop end (extended side) Origin Machine stop end (retracted side) Cable holder (with screws) Shipped with product Machine screw for ground 4 [0.157] Shipped with product V-groove (For reference plane identification)

Open the catalog to page 7
Electric actuator IVM - 8

Machine stop end (extended side) Machine stop end (retracted side) Stroke Cable holder (with screws) Shipped with product (1.9 [0.075]) 4 [0.157] Machine screw for ground Shipped with product

Open the catalog to page 8
Electric actuator IVM - 9

Accessories: I/O cable, power cable

Open the catalog to page 9
Electric actuator IVM - 10

Supplied with controller Terminal location • Power cable Terminal location Additional Parts Actuator cable Terminal location Terminal location Included cable Blank : USB (min-B) male N : Cable not included

Open the catalog to page 10
Electric actuator IVM - 11

Controller wiring method Communication cable

Open the catalog to page 11
Electric actuator IVM - 12

Specifications Model Item Power Indicators Power supply voltage Consumption current 24VDC (supplied from controller) Setting display Power indicators LED lighted (internal 5V) while power is on Setting method Communication protocol Cable length General Operating temperature/humidity range Storage temperature Noise resistance Easy Normal

Open the catalog to page 12
Electric actuator IVM - 13

AUTOMAX S.A. Z.A. Rue de Champ Chardon 41250 MONT PRES CHAMBORD - FRANCE E-mail: info@automax.fr www.automax.fr

Open the catalog to page 13

All AUTOMAX catalogs and technical brochures

  1. Vacuum Filter

    12 Pages

  2. Vacuum Valve

    28 Pages

  3. Flow sensor

    36 Pages