| 9
Explosion protection
For the installation of valve gearboxes in potentially explosive
atmospheres, special protective measures are required.
AUMA gearboxes are approved for installation in potentially
explosive zones.
They comply with the regulations stipulated in European
standard EN 13463-1 et seqq. AUMA certifies this in a declaration
of incorporation.
Classification of explosion protection
” II2G c IIC T4 according to ATEX 94/9/EC
Corrosion protection/colour
Standard (KN)
The standard AUMA corrosion protection KN is a high
quality coating. This is suitable for outdoor installation and
for slightly aggressive atmospheres with a low level of
pollution.
KS
AUMA recommends this corrosion protection class for
installation in occasionally or permanently aggressive atmospheres
with a moderate pollutant concentration.
KX
AUMA recommends this corrosion protection class for
installation in aggressive atmosphere with high humidity and
a high pollutant concentration.
Colour
The standard colour of the finish coating is silver-grey (similar
to RAL 7037). Other colours are available on request.
|
|